上海交通大学学报(英文版) ›› 2014, Vol. 19 ›› Issue (6): 706-711.doi: 10.1007/s12204-014-1570-y
YANG Shun-gang1 (杨顺刚), Gong Xia2 (龚霞), WEI Sheng-kai1 (魏盛凯), GU Xin-feng1 (顾鑫锋), SHI Jeremy3 (施力玮), JIANG Chuan4 (江川), WAN Da-qian4 (万大千), WANG Jin-wu4* (王金武), DAI Ke-rong4* (戴尅戎), YAN Meng-ning4 (严孟宁)
出版日期:
2014-12-31
发布日期:
2014-12-08
通讯作者:
WANG Jin-wu (王金武), DAI Ke-rong (戴尅戎)
E-mail: jinwu wang.dr@gmail.com, krdai@163.com
YANG Shun-gang1 (杨顺刚), Gong Xia2 (龚霞), WEI Sheng-kai1 (魏盛凯), GU Xin-feng1 (顾鑫锋), SHI Jeremy3 (施力玮), JIANG Chuan4 (江川), WAN Da-qian4 (万大千), WANG Jin-wu4* (王金武), DAI Ke-rong4* (戴尅戎), YAN Meng-ning4 (严孟宁)
Online:
2014-12-31
Published:
2014-12-08
Contact:
WANG Jin-wu (王金武), DAI Ke-rong (戴尅戎)
E-mail: jinwu wang.dr@gmail.com, krdai@163.com
摘要: Neuromuscular electrical stimulation has been studied to be a method of prophylaxis for deep venous thrombosis by activating the calf muscle pump. However, there is little evidence of the effects of different stimulating parameters on hemodynamics and comfort levels. The objective of this paper is to compare the effects of different stimulating parameters (current amplitude, pulse-width) on hemodynamic alterations of the popliteal vein and the comfort levels in a group of fourteen healthy subjects. Doppler ultrasound detection of peak venous velocity and blood volume were taken from baseline, twelve sequential electrical stimulations and foot dorsiflexion for each subject. A visual analogue scale was used to assess the subjects’ pain perception of neuromuscular electrical stimulation. The results showed that peak venous velocity and blood volume augmented as current amplitude and pulse-width increased while pain level also increased. A compromise was reached that parameters consisting of an amplitude of 10mA and a pulse-width of 500 μs would obtain a high-peak venous velocity and blood flow volume with a relatively comfortable perception. In addition, parameters consisting of an amplitude of 20mA and a pulse-width of 300 μs were also shown to be a promising choice. However, further studies need to be done to validate and enrich these findings.
中图分类号:
YANG Shun-gang1 (杨顺刚), Gong Xia2 (龚霞), WEI Sheng-kai1 (魏盛凯), GU Xin-feng1 (顾鑫锋),. A Hemodynamic Study of the Effect of Neuromuscular Electrical Stimulation on Enhancing Popliteal Venous Flow[J]. 上海交通大学学报(英文版), 2014, 19(6): 706-711.
YANG Shun-gang1 (杨顺刚), Gong Xia2 (龚霞), WEI Sheng-kai1 (魏盛凯), GU Xin-feng1 (顾鑫锋), SHI Jeremy3 (施力玮), JIANG Chuan4 (江川), WAN Da-qian4 (万大千), WANG Jin-wu4* (王金武), DAI Ke-rong4* (戴尅戎), YAN Meng-ning4 (严孟宁. A Hemodynamic Study of the Effect of Neuromuscular Electrical Stimulation on Enhancing Popliteal Venous Flow[J]. Journal of shanghai Jiaotong University (Science), 2014, 19(6): 706-711.
[1] Gogalniceanu P, Johnston C J, Khalid U, et al.Indications for thrombolysis in deep venous thrombosis [J]. European Journal of Vascular and Endovascular Surgury, 2009, 38(2): 192-198. [2] Geerts W H, Bergqrist D, Pineo G F, et al. Prevention of venous thromboembolism: American college of chest physicians evidence-based clinical practice guidelines [J]. Chest Journal, 2008, 133(6 sup):381S-453S. [3] Kahn S R. The post thrombotic syndrome [J]. Thrombosis Research, 2011, 127(3 sup): S89-S92. [4] Froimson M I, Murray T G, Fazekas A F. Venous thromboembolic disease reduction with a portable pneumatic compression device [J]. Journal of Arthroplasty,2009, 24(2): 310-316. [5] Maclellan D G, Fletcher J P. Mechanical compression in the prophylaxis of venous thromboembolism [J]. ANZ Journal of Surgery, 2007, 77(6): 418-423. [6] Broderick B J, O’Briain D E, Kearns S R, et al. A hemodynamic study of popliteal vein blood flow:The effect of bed rest and electrically elicited calf muscle contractions [C]//31st Annual International Conference of the IEEE EMBS Minneapolis. Minnesota,USA: IEEE, 2009. [7] Broderick B J, O’Briain D E, Breen P P, et al. A pilot evaluation of a neuromuscular electrical stimulation (NMES) based methodology for the prevention of venous stasis during bed rest [J]. Medical Engineering & Physics, 2010, 32(4): 349-355. [8] Griffin M, Nicolaides A N, Bond D, et al. The efficacy of a new stimulation technology to increase venous flow and prevent venous stasis [J]. European Journal of Vascular and Endovascular Surgery, 2010,40(6): 766-771. [9] Izumi M, Ikeuchi M, Mitani T, et al. Prevention of venous stasis in the lower limb by transcutaneous electrical nerve stimulation [J]. European Journal of Vascular and Endovascular Surgery, 2010, 39(5): 642-645. [10] Broderick B J, Kennedy C, Breen P P, et al. Patient tolerance of neuromuscular electrical stimulation (NMES) in the presence of orthopaedic implants [J].Medical Engineering & Physics, 2011, 33(1): 56-61. [11] Lyons G M, Leane G E, Grace P A. The effect of electrical stimulation of the calf muscle and compression stocking on venous blood flow velocity [J]. European Journal of Vascular and Endovascular Surgery,2002, 23(6): 564-566. [12] Corley G J, Breen P P, Brlea S I, et al. Hemodynamic effects of habituation to a week-long program of neuromuscular electrical stimulation [J]. Medical Engineering & Physics, 2012, 34(4): 459-465. |
[1] | 李明爱1, 2, 魏丽娜1. 基于朴素卷积神经网络和线性插值的运动想像分类[J]. J Shanghai Jiaotong Univ Sci, 2024, 29(6): 958-966. |
[2] | 王雨坤, 丁显廷, 张执南. 基于四电极微流控装置使用介电泳分离循环肿瘤细胞的数值研究[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 391-. |
[3] | 贺雨欣, 张文光, 胥浩天, 徐倚帆, 许李悦. 用于评价神经电极植入行为的精细化脑模型的建立及其模拟行为研究[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 401-. |
[4] | 吴辉,富荣昌,杨晓玉,李现政,王召耀. 三种不同血液粘度模型中分叉血流的数值研究[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 450-. |
[5] | 胡颖涵1, 朱泽宇1, 滕 林2, 何雨石3, 邹德荣1 , 陆家瑜1. 多肽水凝胶在软骨再生工程中的应用[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 468-. |
[6] | 李健1, 2,朱晔1,关天民1. 考虑肌肉因素的脊柱侧弯矫正的数值模拟方法[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 486-. |
[7] | 刘阳1,2,王雅靖1,温大渭1,张全有1,王立1,安美文1,刘勇3. 基底刚度和拓扑结构对人体皮肤成纤维细胞形态的影响[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 495-. |
[8] | 于佳琪1,王殊轶1,王浴屺1,谢华2,吴张檑1,付小妮1,马邦峰1. 基于增强现实技术的新型经皮肾穿刺训练可视化工具[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 517-. |
[9] | 贾菁怡1,李正裔1, 2,彭琳晶1,姚怡飞1. 深部组织压力损伤的早期检测方法:系统综述[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(4): 526-. |
[10] | 高红岩1, 2, 艾孝杰1, 2, 孙正隆3, 陈卫东1, 2, 高安柱1, 2. 手术机器人的力感知技术进展[J]. J Shanghai Jiaotong Univ Sci, 2023, 28(3): 370-381. |
[11] | . [J]. J Shanghai Jiaotong Univ Sci, 2022, 27(2): 168-175. |
[12] | . [J]. J Shanghai Jiaotong Univ Sci, 2022, 27(1): 1-6. |
[13] | . [J]. J Shanghai Jiaotong Univ Sci, 2022, 27(1): 7-14. |
[14] | . [J]. J Shanghai Jiaotong Univ Sci, 2022, 27(1): 15-23. |
[15] | CHENG Rongshan, (程荣山), JIANG Ziang, (蒋子昂), DIMITRIOU Dimitris, GONG Weihua, (龚伟华), TSAI Tsung-Yuan, (蔡宗远). Biomechanical Analysis of Personalised 3D-Printed Clavicle Plates of Different Materials to Treat Midshaft Clavicle Fractures[J]. J Shanghai Jiaotong Univ Sci, 2021, 26(3): 259-266. |
阅读次数 | ||||||||||||||||||||||||||||||||||||||||||||||||||
全文 212
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||
摘要 640
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||