J Shanghai Jiaotong Univ Sci ›› 2021, Vol. 26 ›› Issue (3): 259-266.doi: 10.1007/s12204-021-2291-7
CHENG Rongshan1,2 (程荣山), JIANG Ziang1,2 (蒋子昂), DIMITRIOU Dimitris3, GONG Weihua1,2 (龚伟华), TSAI Tsung-Yuan1,2 (蔡宗远)
出版日期:
2021-06-28
发布日期:
2021-06-02
通讯作者:
GONG Weihua(龚伟华), TSAI Tsung-Yuan (蔡宗远)
E-mail:gwh1124@sina.com, tytsai@sjtu.edu.cn
基金资助:
CHENG Rongshan1,2 (程荣山), JIANG Ziang1,2 (蒋子昂), DIMITRIOU Dimitris3, GONG Weihua1,2 (龚伟华), TSAI Tsung-Yuan1,2 (蔡宗远)
Online:
2021-06-28
Published:
2021-06-02
Contact:
GONG Weihua(龚伟华), TSAI Tsung-Yuan (蔡宗远)
E-mail:gwh1124@sina.com, tytsai@sjtu.edu.cn
Supported by:
摘要: This study was aimed at comparing the biomechanical performance of personalised 3D-printed clavicle plates of different materials to treat midshaft clavicle fractures with the finite element (FE) method. The FE model of a fractured clavicle with a personalised 3D-printed clavicle plate and screws was constructed. Three types of materials were simulated, including stainless steel, titanium alloy, and magnesium alloy. Two loading conditions (axial compression and inferior bending) were applied at the distal end of the clavicle to simulate arm abduction. Plate stiffness, peak stress, and bone strain at the clavicle fracture site were measured and compared. The stiffness of the stainless steel clavicle plate was significantly greater than that of the titanium alloy clavicle plate. The stiffness of the magnesium alloy clavicle plate was similar to that of the intact clavicle; peak stress of the magnesium alloy clavicle plate was the lowest; thus, it had less stress-shielding effects on bone formation. The magnesium alloy clavicle plate was more likely to form bone by distributing proper strain at the clavicle fracture site. According to the influence of different materials on the tensile strength, magnesium alloy clavicle plates might be preferred owing to their bionic stiffness in the treatment of patients with a low risk of falling. For patients who engage in contact sports, a titanium alloy clavicle plate might be more suitable.
中图分类号:
CHENG Rongshan, (程荣山), JIANG Ziang, (蒋子昂), DIMITRIOU Dimitris, GONG Weihua, (龚伟华), TSAI Tsung-Yuan, (蔡宗远). Biomechanical Analysis of Personalised 3D-Printed Clavicle Plates of Different Materials to Treat Midshaft Clavicle Fractures[J]. J Shanghai Jiaotong Univ Sci, 2021, 26(3): 259-266.
CHENG Rongshan, (程荣山), JIANG Ziang, (蒋子昂), DIMITRIOU Dimitris, GONG Weihua, (龚伟华), TSAI Tsung-Yuan, (蔡宗远). Biomechanical Analysis of Personalised 3D-Printed Clavicle Plates of Different Materials to Treat Midshaft Clavicle Fractures[J]. J Shanghai Jiaotong Univ Sci, 2021, 26(3): 259-266.
[1] | KHAN L A K, BRADNOCK T J, SCOTT C, et al. Fractures of |
the clavicle [J]. The Journal of Bone and Joint Surgery -American Volume, 2009, | |
91 | (2): 447- 460. |
[2] | NOWAK J, MALLMIN H, LARSSON S. The aetiology and |
epidemiology of clavicular fractures: A prospective study during a two-year | |
period in Uppsala, Sweden [J]. Injury, 2000, 31(5): 353-358. | |
[3] | VANDER HAVE K L, PERDUE A M, CAIRD M S, et al. Operative |
versus nonoperative treatment of midshaft clavicle fractures in adolescents | |
[J] | Journal of Pediatric Orthopedics, 2010, 30(4): 307-312. |
[4] | Canadian Orthopaedic Trauma Society. Nonoperative treatment |
compared with plate fixation of displaced midshaft clavicular fractures [J]. | |
The Journal of Bone & Joint Surgery, 2007, 89(1): 1-10. | |
[5] | KULSHRESTHA V, ROY T, AUDIGE L. Operative versus |
nonoperative management of displaced midshaft clavicle fractures: A prospective | |
cohort study [J]. Journal of Orthopaedic Trauma, 2011, 25(1): 31-38. | |
[6] | MIRZATOLOOEI F. Comparison between operative and |
nonoperative treatment methods in the management of comminuted fractures of the | |
clavicle [J]. Acta Orthopaedica et Traumatologica Turcica, 2011, 45(1): 34-40. | |
[7] | NI M, NIU W X, WONG D W C, et al. Finite element analysis |
of locking plate and two types of intramedullary nails for treating mid-shaft | |
clavicle fractures [J]. Injury, 2016, 47(8): 1618-1623. | |
[8] | ZLOWODZKI M, ZELLE B A, COLE P A, et al. Treatment of |
acute midshaft clavicle fractures: Systematic review of 2 144 fractures: On | |
behalf of the Evidence-Based Orthopaedic Trauma Working Group [J]. Journal of | |
Orthopaedic Trauma, 2005, 19(7): 504- 507. | |
[9] | PENGRUNG N, LAKDEE N, PUNCREOBUTR C, et al. Finite |
element analysis comparison between superior clavicle locking plate with and | |
without screw holes above fracture zone in midshaft clavicular fracture [J]. BMC | |
Musculoskeletal Disorders, 2019, 20(1): 465. | |
[10] | NIINOMI M, NAKAI M. Titanium-based biomaterials for |
preventing stress shielding between implant devices and bone [J]. International | |
Journal of Biomaterials, 2011, 2011: 836587. | |
[11] | GARDNER M J, EVANS J M, DUNBAR R P. Failure of fracture |
plate fixation [J]. The Journal of the American Academy of Orthopaedic | |
Surgeons, 2009, 17(10): 647-657. | |
[12] | LAU T W, LEUNG F, CHAN C F, et al. Wound complication of |
minimally invasive plate osteosynthesis in distal tibia fractures [J]. | |
International Orthopaedics, 2007, 32(5): 697-703. [13] HAASE K, ROUHI G. A | |
discussion on plating factors that affect stress shielding using finite element | |
analysis [J]. Journal of Biomechanical Science and Engineering, 2010, 5(2): | |
12 | 9-141. |
[14] | LI J L, QIN L, YANG K, et al. Materials evolution of bone |
plates for internal fixation of bone fractures: A review [J]. Journal of | |
Materials Science & Technology, 2020, 36: 190-208. [15] STAIGER M P, PIETAK | |
A M, HUADMAI J, et al. Magnesium and its alloys as orthopedic biomaterials: A | |
review [J]. Biomaterials, 2006, 27(9): 1728-1734. | |
[16] | FANG R X, JI A M, ZHAO Z H, et al. A regression |
orthogonal biomechanical analysis of internal fixation for femoral shaft | |
fracture [J]. Biocybernetics and Biomedical Engineering, 2020, 40(3): | |
12 | 77-1290. |
[17] | LIU P C, YANG Y J, LIU R, et al. A study on the |
mechanical characteristics of the EBM-printed Ti-6Al-4V LCP plates in vitro | |
[J] | Journal of Orthopaedic Surgery and Research, 2014, 9(1): 106. |
[18] | ZENG L Q, WEI H F, LIU Y J, et al. Titanium elastic nail |
(TEN) | versus reconstruction plate repair of midshaft clavicular fractures: A |
finite element study [J]. PLoS One, 2015, 10(5): e0126131. | |
[19] | ˇSEˇSOK A, VAITIEK¯UNAS M. Modelling of bone fixation plate |
from biodegradable magnesium alloy [J]. Mokslas - Lietuvos Ateitis/Science | |
-Future of Lithuania, 2019, 11: mla.2019.7092 | |
[20] | FAVRE P, KLOEN P, HELFET D L, et al. Superior versus |
anteroinferior plating of the clavicle: A finite element study [J]. Journal of | |
Orthopaedic Trauma, 2011, 25(11): 661-665. [21] RHO J Y, HOBATHO M C, ASHMAN R | |
B. Relations of mechanical properties to density and CT numbers in human bone | |
[J] | Medical Engineering & Physics, 1995, 17(5): 347-355. [22] DROSDOWECH D |
S, MANWELL S E, FERREIRA L M, et al. Biomechanical analysis of fixation of | |
middle third fractures of the clavicle [J]. Journal of Orthopaedic Trauma, | |
20 | 11, 25(1): 39-43. |
[23] | CRONSK¨AR M, RASMUSSEN J, TINNSTEN M. Combined finite |
element and multibody musculoskeletal investigation of a fractured clavicle | |
with reconstruction plate [J]. Computer Methods in Biomechanics and Biomedical | |
Engineering, 2015, 18(7): 740-748. | |
[24] | TOKSVIG-LARSEN S, RYD L. Surface characteristics following |
tibial preparation during total knee arthroplasty [J]. The Journal of | |
Arthroplasty, 1994, 9(1): 63-66. | |
[25] | CHIU Y C, HUANG K C, SHIH C M, et al. Comparison of |
implant failure rates of different plates for midshaft clavicular fractures | |
based on fracture classifications [J]. Journal of Orthopaedic Surgery and | |
Research, 2019, 14(1): 220. | |
[26] | ZHANG X J, CHENG X D, YIN B, et al. Finite element analysis |
of spiral plate and Herbert screw fixation for treatment of midshaft clavicle | |
fractures [J]. Medicine, 2019, 98(34): e16898. [27] WILSON D J, WEAVER D L, | |
BALOG T P, et al. Early postoperative failure of a new intramedullary fixation | |
device for midshaft clavicle fractures [J]. Orthopedics, 2013, 36(11): | |
e1450-e1453. | |
[28] | CHEN J H, LIU C, YOU L D, et al. Boning up on Wolff’s |
Law: Mechanical regulation of the cells that make and maintain bone [J]. | |
Journal of Biomechanics, 2010, 43(1): 108-118. | |
[29] | WU Z Y, LIU Y P, SINGARE S, et al. Animal model for |
evaluation of strain gauge in mandibular distraction osteogenesis in rabbits | |
[J] | British Journal of Oral and Maxillofacial Surgery, 2007, 45(8): 633-636. |
[30] | ZHANG F X, CHEN F C, QI Y H, et al. Finite |
element analysis of dual small plate fixation and single plate fixation for | |
treatment of midshaft clavicle fractures [J]. Journal of Orthopaedic Surgery | |
and Research, 2020, 15(1): 148. |
[1] | FENG Qiping (冯齐平), CHU Fengting (储沨婷), CHEN Rongjing (陈荣敬), PAN Xiaogang (潘晓岗). Effects of Mandibular Extractions with Clear Aligners: A Finite Element Analysis[J]. J Shanghai Jiaotong Univ Sci, 2021, 26(3): 377-382. |
[2] | PAN Shengxuan (潘晟轩), ZOU Diyang (邹第洋), PAN Xiaogang(潘晓岗), TSAI Tsung-Yuan (蔡宗远). Effect of Attachment on Movement Control of the Central Incisor Using Invisible Orthodontics: In-Silico Finite Element Analysis[J]. J Shanghai Jiaotong Univ Sci, 2021, 26(3): 383-390. |
[3] | ZHOU Xuhui (周旭辉), ZHANG Wenguang (张文光), XIE Jie (谢颉). Effects of Micro-Milling and Laser Engraving on Processing Quality and Implantation Mechanics of PEG-Dexamethasone Coated Neural Probe[J]. J Shanghai Jiaotong Univ Sci, 2021, 26(1): 1-9. |
[4] | LUO Mai-sheng1 (罗买生), XIE Hong-zhi2 (谢洪智), XIE Le3 (谢叻),CAI Ping4 (蔡萍), GU Li-xu. Robust and Real-Time Guidewire Simulation Based on Kirchhoff Elastic Rod for Vascular Intervention Training[J]. 上海交通大学学报(英文版), 2014, 19(5): 624-629. |
阅读次数 | ||||||
全文 |
|
|||||
摘要 |
|
|||||