J Shanghai Jiaotong Univ Sci ›› 2022, Vol. 27 ›› Issue (2): 240-249.doi: 10.1007/s12204-021-2324-2
• Medicine-Engineering Interdisciplinary Research • Previous Articles Next Articles
LIU Xiaoying1 * (刘晓颖), YUE Yong1 (岳勇), WANG Chongning1 (王宠宁), HUANG Jiazan1 (黄家赞),HUANG Xianwei2 (黄贤伟), HAO Yanhua1 (郝艳华)
Received:2020-11-13
Online:2022-03-28
Published:2022-05-02
CLC Number:
LIU Xiaoying* (刘晓颖), YUE Yong(岳勇), WANG Chongning (王宠宁), HUANG Jiazan (黄家赞),HUANG Xianwei(黄贤伟), HAO Yanhua(郝艳华). Topology Optimization Method for Calcaneal Prosthesis[J]. J Shanghai Jiaotong Univ Sci, 2022, 27(2): 240-249.
| [1] | BREKELMANS W A M, POORT H W, SLOOFF T J J H. A new method to analyse the mechanical behaviour of skeletal parts [J]. Acta Orthopaedica Scandinavica,1972, 43(5): 301-317. |
| [2] | PATIL K M, BRAAK L H, HUSON A. Analysis of stresses in two-dimensional models of normal and neuropathic feet [J]. Medical and Biological Engineering and Computing, 1996, 34(4): 280-284. |
| [3] | JACOB S, PATIL K M, BRAAK L H, et al. Stresses in a 3D two arch model of a normal human foot [J]. Mechanics Research Communications, 1996, 23(4): 387-393. |
| [4] | JACOB S, PATIL M K. Three-dimensional foot modeling and analysis of stresses in normal and early stage Hansen’s disease with muscle paralysis [J]. Journal of Rehabilitation Research and Development, 1999, 36(3):252-263. |
| [5] | CHU T M, REDDY N P, PADOVAN J. Threedimensional finite element stress analysis of the polypropylene, ankle-foot orthosis: Static analysis [J].Medical Engineering & Physics, 1995, 17(5): 372-379. |
| [6] | HU Y C, ZHAO S T, HOU J Y, et al. Sensitivity analysis about influence factors on stability of hip prosthesis[J]. Journal of Mechanical Engineering, 2015, 51(9):45-50 (in Chinese). |
| [7] | RUATTI S, CORBET C, BOUDISSA M, et al. Total talar prosthesis replacement after talar extrusion [J].The Journal of Foot and Ankle Surgery, 2017, 56(4):905-909. |
| [8] | TRACEY J, ARORA D, GROSS C E, et al. Custom 3D-printed total talar prostheses restore normal joint anatomy throughout the hindfoot [J]. Foot & Ankle Specialist, 2019, 12(1): 39-48. |
| [9] | IMANISHI J, CHOONG P F M. Three-dimensional printed calcaneal prosthesis following total calcanectomy[J]. International Journal of Surgery Case Reports,2015, 10: 83-87. |
| [10] | REN X, YANG L, DUAN X J. Three-dimensional printing in the surgical treatment of osteoid osteoma of the calcaneus: A case report [J]. Journal of International Medical Research, 2017, 45(1): 372-380. |
| [11] | HARRISW H. Will stress shielding limit the longevity of cemented femoral components of total hip replacement?[J]. Clinical Orthopaedics and Related Research,1992(274): 120-123. |
| [12] | LEWIS J L, ASKEW M J, WIXSON R L, et al. The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component [J]. Journal of Bone and Joint Surgery, 1984, 66(2): 280-286. |
| [13] | SUN M. Discussion on functional adaptability and stress shielding effect of bone [J]. Beijing Biomedical Engineering, 1995, 14(3): 178-179 (in Chinese). |
| [14] | WANG X, XU S, ZHOU S, et al. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: A review [J]. Biomaterials,2016, 83: 127-141. |
| [15] | GOGARTY E, PASINI D. Hierarchical topology optimization for bone tissue scaffold: preliminary results on the design of a fracture fixation plate [M]//Engineering and applied sciences optimization.Cham: Springer, 2015: 311-340 |
| [16] | AL-TAMIMI A A, PEACH C, FERNANDES P R, et al. Topology optimization to reduce the stress shielding effect for orthopedic applications [J]. Procedia CIRP,2017, 65: 202-206. |
| [17] | RAHIMIZADEH A, NOURMOHAMMADI Z, ARABNEJAD S, et al. Porous architected biomaterial for a tibial-knee implant with minimum bone resorption and bone-implant interface micromotion [J]. Journal of the Mechanical Behavior of Biomedical Materials,2018, 78: 465-479. |
| [18] | TAO K, WANG D M, WANG C T, et al. Effects of ligaments and plantar fascia on the foot finite element analysis [J]. Journal of Biomedical Engineering, 2008,25(2): 336-340. |
| [19] | QIAN Z H. Dynamic finite element modeling and biomechanical function coupling analysis of the human foot complex during locomotion [D]. Jilin, China: Jilin University, 2010. |
| [20] | ZHANG M, CHEUNG JASON T M, YU J, et al. Human foot three-dimensional finite element of modeling and its biomechanical applications [J]. Journal of Medical Biomechanics, 2007, 22(4): 339-344 (in Chinese). |
| [21] | FROST H M. A 2003 update of bone physiology and Wolff’s Law for clinicians [J]. The Angle Orthodontist,2004, 74(1): 3-15. |
| [22] | WOLFF J. The law of bone remodeling [M]. New York:Springer, 1986. |
| [23] | LIU L L. Convergence criteria for topology optimization of titanium alloy prosthesis and its application [D].Changchun, China: Changchun University of Science and Technology, 2018 (in Chinese). |
| [1] | Zhang Dong, Liu Sheng, Shi Mengyao, Cai Yu, Wang Dazhong. Misaligned Parallel-Chamber Soft Pneumatic Network Actuator for Multi-Mode Gripping [J]. J Shanghai Jiaotong Univ Sci, 2026, 31(1): 59-70. |
| [2] | LI Tian, JI Zhiyuan, LI Bosheng, et al. Research on Engineering Applications of Intelligent Piping Stress Analysis Software Start-Prof [J]. Ocean Engineering Equipment and Technology, 2026, 13(1): 84-93. |
| [3] | YANG Hao, TANG Weiqin. Experiment and Crystal Plasticity Simulation of Forming Limit of Quenching Partitioning Steel [J]. Journal of Shanghai Jiao Tong University, 2025, 59(8): 1181-1191. |
| [4] | YIN Xu, CAO Donghui, TIAN Geng, YANG Zhixun, FAN Zhirui, WANG Gang, LU Yucheng, WANG Hui. Automatic Filling Optimization Design of Filler Bodies in Umbilical Cross-Section Based on Quasi-Physical Algorithm [J]. Journal of Shanghai Jiao Tong University, 2025, 59(8): 1103-1113. |
| [5] | NA Pengyue, WU Zhen, LIU Qi, HUO Junzhou. Life Analysis of Wear Fatigue Competition Failure Mechanism of Main Bearing of Boring Machine [J]. Journal of Shanghai Jiao Tong University, 2025, 59(5): 675-683. |
| [6] | Chen Huiran, Fu Rongchang, Yang Xiaozheng, Li Pengju, Wang Kun. Effect of Stride Length on Knee Contact [J]. J Shanghai Jiaotong Univ Sci, 2025, 30(4): 759-767. |
| [7] | Li Pengju, Fu Rongchang, Yang Xiaozheng, Wang Kun. Dynamic Response of Idiopathic Scoliosis and Kyphosis Spine [J]. J Shanghai Jiaotong Univ Sci, 2025, 30(3): 482-492. |
| [8] | MAO Liang, SHOU Jianlin, LIU Xuchen. Analysis of the Influence of Vibration-Blocking Mass on Vibration Transmission Performance of Marine Auxiliary Machinery [J]. Ocean Engineering Equipment and Technology, 2025, 12(3): 128-131. |
| [9] | ZHANG Lin, ZHANG Bin, SHI Hemu. Fatigue Analysis Affected by Out-of-Plane Bendingfor Mooring Chain of a Floating Offshore Structure [J]. Ocean Engineering Equipment and Technology, 2025, 12(2): 166-172. |
| [10] | LIU Yixiang, LI Peng, LIU Jiannan, WANG Kun, SHI Hemu. Finite Element Analysis and Monitoring Scheme Design for the MCM of a Submerged Turret Production Single-Point Mooring System [J]. Ocean Engineering Equipment and Technology, 2025, 12(2): 120-126. |
| [11] | HUANG Zhidi, GAO Jianxiong, MENG Lingchao, CHENG Qin, LI Miaomiao. Prediction of Tensile Strength of Open-Cell Composite Laminates Considering Stress Relief Effects [J]. Journal of Shanghai Jiao Tong University, 2025, 59(12): 1929-1941. |
| [12] | GUO Li, YUAN Yuchao, TANG Wenyong. Inversion of Displacement Field of Marine Slender Pipelines Under Three-Dimensional Background Ocean Currents [J]. Journal of Shanghai Jiao Tong University, 2025, 59(12): 1815-1823. |
| [13] | XU Yang, XIAO Qian, JIA Hongjie, JIN Yu, MU Yunfei, LU Wenbiao. Junction Temperature Algorithm of IGBT for Interface Converter in Optical Storage Microgrid System Considering Three-Dimensional Transverse Heat Conduction [J]. Journal of Shanghai Jiao Tong University, 2025, 59(10): 1533-1545. |
| [14] | JIANG Jie, CHEN Lijun, CHAI Wencheng, AI Yonglin, OU Xiaoduo, GONG Jian. Force and Deformation Analysis of H(t)-T Loaded Pile Based on Pasternak Foundation Model [J]. Journal of Shanghai Jiao Tong University, 2025, 59(1): 60-69. |
| [15] | YE Peng (叶鹏), FU Rongchang∗ (富荣昌), WANG Zhaoyao (王召耀). Adjacent Segment Biomechanical Changes After Implantation of Cage Plus Plate or Zero-Profile Device in Different Segmental Anterior Cervical Discectomy and Fusion [J]. J Shanghai Jiaotong Univ Sci, 2025, 30(1): 166-174. |
| Viewed | ||||||
|
Full text |
|
|||||
|
Abstract |
|
|||||