上海交通大学学报(英文版) ›› 2017, Vol. 22 ›› Issue (2): 133-138.doi: 10.1007/s12204-017-1812-x

• • 上一篇    下一篇

Performance Evaluation of Energy Meters Under Nonlinear Loads

GUL Mehr1,2*, TAI Nengling1 (邰能灵), MAHAR Mukhtiar Ahmed3,HUANG Wentao1 (黄文焘), LARIK Abdul Sattar3   

  1. (1. Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; 2. Department of Electrical Engineering, Balochistan University of Information Technology, Engineering and Management Sciences (BUITEMS), Quetta 87300, Balochistan, Pakistan; 3. Department of Electrical Engineering, Mehran University of Engineering & Technology, Jamshoro 76062, Sindh, Pakistan)
  • 出版日期:2017-03-31 发布日期:2017-04-04
  • 通讯作者: GUL Mehr E-mail:mehrbuitms@gmail.com

Performance Evaluation of Energy Meters Under Nonlinear Loads

GUL Mehr1,2*, TAI Nengling1 (邰能灵), MAHAR Mukhtiar Ahmed3,HUANG Wentao1 (黄文焘), LARIK Abdul Sattar3   

  1. (1. Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China; 2. Department of Electrical Engineering, Balochistan University of Information Technology, Engineering and Management Sciences (BUITEMS), Quetta 87300, Balochistan, Pakistan; 3. Department of Electrical Engineering, Mehran University of Engineering & Technology, Jamshoro 76062, Sindh, Pakistan)
  • Online:2017-03-31 Published:2017-04-04
  • Contact: GUL Mehr E-mail:mehrbuitms@gmail.com

摘要:

Due to rapid advancements in power electronics, the utilization of electronically switched loads and nonlinear loads is increasing gradually in the electrical power system. These loads create problems of measuring instruments, when connected to the power distribution systems. In this paper, an experimental investigation has been carried out to analyze the performance of single-phase watt-hour (induction and electronic types) energy meters that are being used in Pakistan. The accuracy of the energy meters has been tested under different household nonlinear loads, at various power factors and also at different supply voltage levels. Power factor and total harmonic distortion (THD) of different household loads are also recorded in the experimental work. A hardware based experimental setup has been designed to perform the experimental work. The experimental results have been compared to Water and Power Development Authority (WAPDA) standards for energy meters.

关键词: energy meter accuracy, nonlinear loads, experimental investigation, harmonic distortion, power factor

Abstract:

Due to rapid advancements in power electronics, the utilization of electronically switched loads and nonlinear loads is increasing gradually in the electrical power system. These loads create problems of measuring instruments, when connected to the power distribution systems. In this paper, an experimental investigation has been carried out to analyze the performance of single-phase watt-hour (induction and electronic types) energy meters that are being used in Pakistan. The accuracy of the energy meters has been tested under different household nonlinear loads, at various power factors and also at different supply voltage levels. Power factor and total harmonic distortion (THD) of different household loads are also recorded in the experimental work. A hardware based experimental setup has been designed to perform the experimental work. The experimental results have been compared to Water and Power Development Authority (WAPDA) standards for energy meters.

Key words: energy meter accuracy, nonlinear loads, experimental investigation, harmonic distortion, power factor