Journal of Shanghai Jiao Tong University ›› 2021, Vol. 55 ›› Issue (2): 179-187.doi: 10.16183/j.cnki.jsjtu.2020.061

Special Issue: 《上海交通大学学报》2021年12期专题汇总专辑 《上海交通大学学报》2021年“机械工程”专题

Previous Articles     Next Articles

Experimental Study of a Trans-Critical CO2 Mobile Air Conditioning System with an Ejector

LI Hao, ZHANG Zhenyu, SONG Xia, CHEN Jiangping()   

  1. Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200240, China
  • Received:2020-03-09 Online:2021-02-01 Published:2021-03-03
  • Contact: CHEN Jiangping E-mail:jpchen_sjtu@163.com

Abstract:

A carbon dioxide(CO2) ejector expansion air conditioning system for vehicles is developed in a calorimeter laboratory. In experimental tests on a standard mobile air conditioning bench, the effects of different operating parameters on the performance of the CO2 refrigeration system for vehicles are studied, and the performance advantages of the CO2 ejector expansion refrigeration system are comparatively analyzed. The research results show that the cooling capacity of the CO2 ejector expansion refrigeration system for vehicles is almost equal to that of the CO2 conventional cooling system. Both increasing the indoor air flow rate and increasing the compressor speed can effectively increase the cooling capacity of the CO2 ejector expansion refrigeration system, and the ejector can increase the coefficient of performance (COP) of the system by 1.65% to 12.60% under different working conditions. The outdoor temperature has a great impact on the CO2 ejector expansion refrigeration system performance, and the performance of CO2 ejector expansion refrigeration system for vehicles decays obviously at a high ambient temperature.

Key words: carbon dioxide(CO2), ejector, trans-critical cycle, mobile air conditioning, performance

CLC Number: