Journal of Shanghai Jiaotong University ›› 2012, Vol. 46 ›› Issue (04): 657-660.

• General Industrial Technology • Previous Articles    

Sensitivity of Physiological Parameters in Different Indoor Environment

 PAN  Li-1, LIAN  Zhi-Wei-1, SUN  Bi-Ying-2, DONG  Li-2, YE  Jian-Jun-3   

  1. (1. School of Mechanical Engineering, Shanghai Jiaotong University, Shanghai 200240, China;2. School of Medicine, Shanghai Jiaotong University, Shanghai 200025, China;3. Shanghai Research Institute of Building Sciences, Shanghai 201108, China)
  • Received:2010-11-30 Online:2012-04-28 Published:2012-04-28

Abstract: Physiological parameters including heart rate (HR), heart rate variability (HRV), blood oxygen saturation (SaO2), finger blood flow (FBF), skin conductance (SC) and respiratory rate (RR) were measured when indoor environmental factors varied in temperature, relative humidity, ventilation, lighting and noise. Sensitivity of these physiological parameters changing towards different environmental factors was statistically analyzed. The results show that HRV, FBF and RR can be combined to evaluate acoustical environment; HRV and SaO2 are suitable for thermal environment; RR can be chosen for fresh air volume changing environment; and FBF and SC can be selected altogether to judge lighting environment.
Key words:

Key words: physiological parameters, indoor environment, sensitivity, comfort