Low Latency Soft Fiberoptic Choledochoscope Robot Control System

  • 周涵巍1,朱心平1,马有为2,王坤东1
Expand
  • (1. School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 200240, Shanghai, China; 2. Shanghai Aerospace Control Technology Institute, Shanghai 201109, China)

Accepted date: 2023-10-10

  Online published: 2025-01-28

Abstract

Soft fiberoptic choledochoscope is an important tool for the diagnose and surgical treatment of biliary disease. However, the traditional soft fiberoptic choledochoscope is hard to operate, due to the low position accuracy. Based on the conventional soft fiberoptic choledochoscope, an electrical soft fiberoptic choledochoscope robot with a low latency was developed. In order to improve the controllability of the conventional choledochoscope, the wire traction mechanism and the rotation mechanism are used to bend and rotate the scope, so as to control its movement orientation. The dead band compensation model and control algorithm of the wire traction mechanism are developed to improve the accuracy of the orientation control. The human-computer interaction system complex motion control system are developed based on ARM emedded system and FPGA. Thanks to the highspeed synchronization channel between FPGA and peripheral, the design of low latency whole-procedure surgical mode was established and verified. Combined with a micro image sensor, real-time video back transmission was realized. The performance of the robot prototype was verified by animal experiment in vivo on a pig. The robot has an extremely low operating latency of no more than 0.402 ms, and a high bending positioning accuracy of ±1.43◦ error margin within 99.7% confidence interval, which guarantees the safety of biliary surgery.

Cite this article

周涵巍1,朱心平1,马有为2,王坤东1 . Low Latency Soft Fiberoptic Choledochoscope Robot Control System[J]. Journal of Shanghai Jiaotong University(Science), 2025 , 30(1) : 43 -52 . DOI: 10.1007/s12204-024-2709-0

References

[1] LI J, MIAO L, ZHOU W C. Research progress of relationship between gastrointestinal tract microecology and cholelithiasis [J]. Chinese Journal of General Surgery, 2020, 29(8): 1000-1005 (in Chinese).
[2] HU Y, ZHANG L, LI W, et al. Design and fabrication of a 3-D printed metallic flexible joint for snakelike surgical robot [J]. IEEE Robotics and Automation Letters, 2019, 4(2): 1557-1563.
[3] LI R, CHEN F, YU W W, et al. A novel cable-driven soft robot for surgery [J]. Journal of Shanghai Jiao Tong University (Science), 2024, 29(1): 60-72.
[4] WU G L, SHI G L. Design and realization of continuum manipulator based on coupling of double parallel mechanism [J]. Journal of Shanghai Jiao Tong University, 2022, 56(6): 809-817 (in Chinese).
[5] JACQUEMIN Q, SUN Q, THUAU D, et al. Design and control of a new electrostrictive polymer based continuum actuator for endoscopic robot [J]. Journal of Intelligent Material Systems and Structures, 2023, 34(12): 1355-1365.
[6] HUANG Y C, TSAI C H, SHIH P C, et al. Control of a robotic flexible endoscope holder for laparoscopic surgery [J]. Journal of Medical Devices, 2021, 15(1): 011112.
[7] ZHANG X, LI W B, CHIU P W Y, et al. A novel flexible robotic endoscope with constrained tendondriven continuum mechanism [J]. IEEE Robotics and Automation Letters, 2020, 5(2): 1366-1372.
[8] ZHONG F X, LI P, SHI J D, et al. Foot-controlled robot-enabled EnDOscope manipulator (FREEDOM) for sinus surgery: Design, control, and evaluation [J]. IEEE Transactions on Biomedical Engineering, 2020, 67(6): 1530-1541.
[9] LIU M X, LIU C, LIU C X. Application of da Vinci surgical robot in metabolic surgery for weight loss [J]. Chinese Journal of Bases and Clinics in General Surgery, 2022, 29(1): 130-134 (in Chinese).
[10] ZHENG S G. Application and evaluation of laparoscopic and robotic-assisted laparoscopic surgery in the treatment of hepatolithiasis [J]. Chinese Journal of Practical Surgery, 2016, 36(3): 289-292 (in Chinese).
[11] GONZALEZ G, BALAKUNTALA M, AGARWAL M, et al. ASAP: A semi autonomous precise system for telesurgery during communication delays [J]. IEEE Transactions on Medical Robotics and Bionics, 2023, 5(1): 66-78.
[12] NANKAKU A, TOKUNAGA M, YONEZAWA H, et al. Maximum acceptable communication delay for the realization of telesurgery [J]. PLoS One, 2022, 17(10): e0274328.
[13] KIBSGAARD M, KRAUS M. Measuring the latency of an augmented reality system for robot-assisted minimally invasive surgery [C]//12th International Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications. Porto: SciTePress, 2017: 321-326.
Outlines

/