The interaction mechanism of three types of vena cava filters (VCFs) with blood vessels and their
influence on the bloodstream during the process of implantation are investigated by finite element method and
computational fluid dynamics. The VCF models are set up with Solidworks software. Using ABAQUS software,
we simulate the working conditions of the VCFs in the vessel to analyze the stress distribution and radial support
stiffness of the vessel wall and the filter surface. Using FLUENT software, we simulate and analyze the velocity,
pressure and shear stress distributions of blood flow when the VCFs are at their working conditions. For the
retrievable VCF (R-VCF), the peak stress at the working conditions of the VCF is the highest, the peak stress
toward the vessel wall is the lowest, and the support stiffness is the lowest. For the permanent VCF (P-VCF), the
peak stress at the working conditions of the VCF is the highest, the peak stress toward the vessel wall is the lowest,
and the support stiffness is the highest. Because of the structure of scaffolding support units and the tendency to
form intimal hyperplasia on their support units, both the convertible VCF (C-VCF) and the P-VCF can embed
their support units in the hyperplasia skin. This effectively prevents them from harming blood veins through
filter damage at the pulse load conditions. As the biomechanical property of the C-VCF is between those of the
R-VCF and the P-VCF, it has smaller obstacle to blood flow after conversion and has some fragmentation effects
on the thrombus. The results show that different types of VCFs differ in their biomechanical and hemodynamic
properties after implantation. Therefore, the simulative analysis can provide a reference basis for filter design and
clinical decision making.
HAN Qingsong (韩青松), CAI Xiangwen (蔡相文), FENG Xiaojuan (冯小娟), ZHANG Qingxiang (张庆祥), FENG Haiquan (冯海全)
. Comparison of Biomechanical Properties and Hemodynamics of Three Different Vena Cava Filters[J]. Journal of Shanghai Jiaotong University(Science), 2018
, 23(6)
: 803
-810
.
DOI: 10.1007/s12204-018-2001-2
[1] LIU W Z, ZHANG L, CHENG X G. Preventive effectof inferior vena caval filter on perioperative pulmonaryembolism for the patients with femoral intertrochantericfracture combined with lower extremitydeep vein thrombosis [J]. Journal of Xinxiang MedicalUniversity, 2015, 32(8): 777-779 (in Chinese).
[2] JOHNSON M S, NEMCEK A A, BENENATI J F, etal. The safety and effectiveness of the retrievable optioninferior vena cava filter: A United States prospectivemulticenter clinical study [J]. Journal of Vascular& Interventional Radiology, 2010, 21(7): 1173-1184.
[3] CHEN L F, CAI X D. Clinical research of inferior venacava filter in preventing 93 cases with lethality pulmonaryembolism [J]. Chinese and Foreign MedicineTreatment, 2017, 36(9): 55-57 (in Chinese).
[4] CHEN L, GU J P, LOUWS, et al. Application of interventionaltreatment combined with intravenous thrombolysisin the treatment of acute pulmonary embolism[J]. Chinese Medical Equipment, 2014, 29(11): 37-40(in Chinese).
[5] HAN J C, LI Z G, WANG J Y. Application of nickeltitanium alloy in vena cava filter [J]. China MedicalEquipment, 2016, 31(4): 75-80 (in Chinese).
[6] GUO F, FENG H Q, HAN Q S, et al. Comparativeanalysis on thrombus filtration efficiency for threekinds of convertible vena cava filters [J]. Journalof Medical Biomechanics, 2017, 32(3): 261-266 (inChinese).
[7] CALKINS H, HINDRICKS G, CAPPATO R, et al.2017 HRS/EHRA/ECAS/APHRS/SOLAECE expertconsensus statement on catheter and surgical ablationof atrial fibrillation: Executive summary [J]. Journal ofInterventional Cardiac Electrophysiology, 2017, 50(1):1-55.
[8] TANG C X, LI E B, LI H Q. Particle image velocimetrybased on wavelength division multiplexing [J]. Opticsand Laser Technology, 2018, 98: 318-325.
[9] HEIKENFELD J, ALLEN S C, STECKL A J. P-59:A novel fluorescent display using light wave couplingtechnology [J]. Sid Symposium Digest of Technical Papers,2004, 35(1): 470-473.
[10] YALLAMPALLI S, IRANI Z??KALVA S P, et al. Endovascularremoval of a permanent “trap ease” inferiorvena cava filter [J]. Vascular and EndovascularSurgery, 2013, 47(5): 379-382.
[11] ZILBERMAN-RUDENKO J, SYLMAN J L, LAKSHMANAN H L S, et al. Dynamics of blood flow andthrombus formation in a multi-bypass microfluidic laddernetwork [J]. Cellular and Molecular Bioengineering,2017, 10(1): 1-14.
[12] NICOL′AS M, LUCEA B, LABORDA A, et al. Influenceof a commercial antithrombotic filter on the cavalblood flow during neutra and Valsalva maneuver [J].Journal of Medical Devices, 2017, 11(3): 031002.
[13] AYCOCK K I, CAMPBELL R L, LYNCH F C, et al.The importance of hemorheology and patient anatomyon the hemodynamics in the inferior vena cava [J]. Annalsof Biomedical Engineering, 2016, 44(12): 1-15.
[14] AYCOCK K I, CAMPBELL R L, MANNING K B, etal. A resolved two-way coupled CFD/6-DOF approachfor predicting embolus transport and the embolustrappingefficiency of IVC filters [J]. Biomechanics &Modeling in Mechanobiology, 2017, 16(3): 851-869.
[15] PAN C J, LIU H Q, WANG Y N, et al. Phase transformationand mechanical behaviors of vena cava filtermodified by deposition of copper-titanium coating [J].Materials Research Bulletin, 2014, 60: 217-221.
[16] ZHOU H J, LIU H F, HUANG H H. Mechanical behaviorof super-elastic home-made NiTi shape memoryalloy bar in tension [J]. Advanced Materials Research,2013, 671-674: 1817-1820.
[17] WANG X M, QUE Z F,WANG Y F, et al. The superelasticmechanical properties of NiTi alloy and its application[M]. Beijing: Science Press, 2009 (in Chinese).
[18] QIU H R, FENG H Q, WANG W H, et al. Analysis onbiomechanical properties and hemodynamics of venacava filters with different numbers of support poles [J].Journal of Medical Biomechanics, 2015, 30(4): 304-310 (in Chinese).
[19] HALABIAN M, KARIMI A, BEIGZADEH B, et al.A numerical study on the hemodynamic and shearstress of double aneurysm through S-shaped vessel[J]. Biomedical Engineering: Applications, Basis andCommunications, 2015, 27(3): 1550033.
[20] GU X Z, CHENG J, LI L J, et al. Experimentalstudy on hemodynamics of vascular stent-coupled systemunder pulsating flow [J]. Life Science Instruments,2017(2): 29-33 (in Chinese).
[21] ZHANG Z Z, QIAO A K, FU W Y. Mechanical analysison treatment of vertebral stenosis by stents withdifferent links [J]. Journal of Medical Biomechanics,2013, 28(1): 44-49 (in Chinese).
[22] ASLAN S. Comparison of the hemodynamic filtering methods and particle filter with extended Kalmanfilter approximated proposal function as an efficienthemodynamic state estimation method [J]. BiomedicalSignal Processing and Control, 2016, 25: 99-107.