An AdBlue dosing control strategy of the selective catalytic reduction (SCR) system is developed for
a heavy-duty diesel (HDD) engine. The strategy includes a raw emission prediction model, an ammonia (NH3)
coverage prediction model, a transient heat hysteresis correction algorithm, an NH3 leakage control model for
transient operation conditions, and a feedback controller (FBC). FBC has been developed by using mathematical
manipulation to change output signal of sensor based on cross-sensitivity of nitrogen oxide (NOx) sensor to NH3.
The quantification of control parameters is based on experiments and Nyquist stability criterion. FBC is enabled
in most test conditions to satisfy the stability requirements. NOx conversion (DeNOx) efficiency of SCR system
is 82.4% in European steady-state cycle (ESC) test and 80.3% in European transient cycle (ETC) test, while the
leakage of NH3 is under 10?5 volume fraction in average.
WANG Tiantian1 (王天田), LIN Feng1* (林峰), HU Jie1 (胡杰),KE Yuqiang2 (柯于强), ZHANG Yueqiu3 (张岳秋)
. Control Strategy Research of a Selective Catalytic Reduction System for Heavy-Duty Application[J]. Journal of Shanghai Jiaotong University(Science), 2017
, 22(5)
: 577
-588
.
DOI: 10.1007/s12204-017-1866-9
[1] SKAF Z, ALIYEV T, SHEAD L, et al. The state ofthe art in selective catalytic reduction control [J]. SAETechnical, 2014. Doi: 10.4271/2014-01-1533 (publishedonline).
[2] ZHANG S M, TIAN F, REN G F, et al. SCR controlstrategy based on ANNs and fuzzy PID in a heavyduty diesel engine [J]. International Journal of AutomotiveTechnology,2012, 13(5): 693-699.
[3] SURENAHALLI H S, PARKER G, JOHNSON J. ExtendedKalman filter estimator for NH3 storage, NO,NO2 and NH3 estimation in a SCR [J]. SAE Technical,2013. Doi: 10.4271/2013-01-1581 (published online).
[4] CHEN P E, WANG J M. Nonlinear and adaptivecontrol of NO/NO2 ratio for improving selective catalyticreduction system performance [J]. Journal of theFranklin Institute. 2013, 350(8): 1992-2012.
[5] HU J, ZHAO Y G, CHEN T, et al. Study of controlstrategy for urea-SCR after-treatment system of heavyduty diesel engine [J]. Chinese Internal CombustionEngine Engineering, 2011, 32(2): 1-5 (in Chinese).
[6] SCH¨AR C M, ONDER C H, GEERING H P. Controlof an SCR catalyst converter system for a mobileheavy-duty application [J]. IEEE Transactions onControl Systems Technology, 2006, 14(4): 641-652.
[7] BLAKEMAN P, ARNBY K, MARSH P, et al.Optimization of an SCR catalyst system to meetEU-IV heavy duty diesel legislation [C]//2008 SAEInternational Powertrains, Fuels and LubricantsCongress. Shanghai: SAE, 2008: 1-8.
[8] DEVARAKONDAM, PARKER G, JOHNSON J H, etal. Model-based control system design in a urea-SCRafter treatment system based on NH3 sensor feedback[J]. International Journal of Automotive Technology,2009, 10(6): 653-662.
[9] HAGA H, HASHIMOTO E, NAKAJIMA K, et al. Newconcept urea-SCR control for super clean diesel vehicle[C]//7th IFAC Symposium on Advances in AutomotiveControl. Tokyo: The International Federation of AutomaticControl, 2013:15-16.
[10] ZHANG H, WANG J M. Ammonia coverage ratio aninput simultaneous estimation in ground vehicle selectivecatalytic reduction (SCR) systems [J]. Journal ofthe Franklin Institute, 2015, 352(2): 708-723.
[11] WILLEMS F, CLOUDT R, VAN DEN EIJNDEN E,et al. Is closed-loop SCR control required to meet futureemission targets [J]. SAE Technical, 2007. Doi:10.4271/2007-01-1574 (published online).
[12] ZHANG H, WANG J M, WANG Y Y. Nonlinear observerdesign of diesel engine selective catalytic reductionsystems with NOx sensor measurements [J].IEEE/ASME Transactions on Mechatronics, 2015,20(4): 1585-1594.
[13] ZHANG H, WANG J M, WANG Y Y. Sensor reductionin diesel engine two-cell selective catalytic reduction(SCR) systems for automotive applications[J]. IEEE/ASME Transactions on Mechatronics, 2015,20(5): 2222-2233.
[14] CHEN P E, WANG J M. Estimation of automotiveurea-based selective catalytic reduction systems duringlow temperature operations [C]//American ControlConference. Portland, Oregon: IEEE, 2014: 1523-1528.
[15] SALANTA G, ZHENG G Y, KOTRBA A, et al.Optimization of a urea SCR system for on-highwaytruck applications [J]. SAE Technical, 2010. Doi:10.4271/2010-01-1938 (published online).
[16] HERMAN A, WU M C, CABUSH D, et al. Modelbased control of SCR dosing and OBD strategies ithfeedback from NH3 sensors [J]. SAE InternationalJournal of Fuels & Lubricants, 2009, 2(1): 375-385.
[17] WILLEMS F, CLOUDT R. Experimental demonstrationof a new model-based SCR control strategy forcleaner heavy-duty diesel engines [J]. IEEE Transactionson Control Systems Technology, 2011, 19(5):1305-1313.
[18] HSIEH M F, WANG J M. Diesel engine selective catalyticreduction (SCR) ammonia surface coverage controlusing a computationally-efficient model predictivecontrol assisted method [C]//ASME 2009 DynamicSystems and Control Conference. Hollywood, California:ASME, 2009: 865-872.
[19] CHEN P E, WANG J M. Sliding-mode observers forurea selective catalytic reduction system state estimationsbased on nitrogen oxide sensor measurements [J].Journal of Automobile Engineering, 2015, 229(7): 835-849.
[20] LIU C B. Research on control strategy and matchingof amino SCR system of diesel engine [D]. Wuhan:School of Automotive Engineering, Wuhan Universityof Technology, 2013 (in Chinese).
[21] Tong D H. Study on control strategy for SCR technologyto reduce NOx emission from heavy-duty dieselengines [D]. Jinan: School of Energy and Power Engineering,Shandong University, 2009 (in Chinese).
[22] SONG Q W, ZHU G. Model-based closed-loop controlof urea SCR exhaust after treatment system fordiesel engine [C]//SAE 2002 World Congress. Detroit,Michigan: SAE, 2002: 1-8.
[23] CHI J N. Control challenges for optimal NOx conversionefficiency from SCR after treatment systems[J]. SAE Technical, 2009. Doi: 10.4271/2009-01-0905(published online).
[24] ZHANG H. NOx sensor ammonia-cross-sensitivity factorestimation in diesel engine selective catalytic reductionsystems [C]//International Conference on Mechatronicsand Control. Jinzhou: IEEE, 2014:1916-1921.
[25] HSIEH M F, WANG J M. Design and experimentalvalidation of an extended Kalman filter-based NOx,concentration estimator in selective catalytic reductionsystem applications [J]. Control Engineering Practice,2011, 19(4): 346-353.
[26] WANG T T, YAN F W, HU J, et al. Feed back controlfor SCR system by cross-sensitivity of the NOx sensorto NH3 [J]. Transactions of CSICE, 2015, 27(5): 417-422 (in Chinese).