Articles

Animal Experiment of Viscose Carbon Fiber Based C/C Composites Applied in Bone Fracture Intramedullary Fixation

Expand
  • (1. College of Mechanical and Electronic Engineering, China University of Petroleum, Qingdao 266580, Shandong, China; 2. No. 2 Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250001, China)

Online published: 2012-11-16

Abstract

The animal experiment of viscose carbon fiber based C/C composites applied in bone defection intramedullary fixation was carried out in New Zealand white rabbits. The histological observation on the 100th day after surgical operation indicated that the experimental animals recovered well and the bone defect area was reconstructed by new bone trabecula. Immunohistochemical observation of leukocyte common antigen and macrophage suggested that intramedullary fixation materials did not induct any chronic toxicity reactions such as inflammatory reactions, macrophage reactions and formation of granulation tissue. The tissue compatibility of this material was excellent. Meanwhile, the impurity element species and the biological toxic element content of viscose fiber based C/C composites were determined by atomic fluorescence analyzer and inductively coupled plasma atomic emission spectrometry. The results reveal that there are few biological toxic elements in the viscose fiber based C/C composites and it can satisfy the constituent demands of surgical implants.

Cite this article

CAO Ning1* (曹宁), WANG Wen-bo2 (王文波), DONG Jian-wen2 (董建文) . Animal Experiment of Viscose Carbon Fiber Based C/C Composites Applied in Bone Fracture Intramedullary Fixation[J]. Journal of Shanghai Jiaotong University(Science), 2012 , 17(5) : 537 -540 . DOI: 10.1007/s12204-012-1321-x

References

[1] Weller S, H¨ontzsch D, Frigg R. Dieepiperiostal,percutaneous plate osteosynthesis: A new minimally invasive technique with reference to “biological osteosythesis”[J]. Unfallchirurg, 1998, 101(2): 115-121.
[2] Witte F, Feyerabend F, Maier P, et al. Biodegradable magnesium-hydroxyapatite metal matrix composites[J]. Biomaterials, 2007, 28(13): 2163-2174.
[3] Buly R L, Huo M H, Salvati E, et al. Titanium wears debris in failed cemented total hip arthroplasty[J]. Journal of Arthroplasty, 1992, 7(3): 315-323.
[4] Jenkins D H R, Forster IW, Mckibbin B M, et al. Induction of tendon and ligament formation by carbon implants [J]. The Journal of Bone and Joint Surgery,1977, 59B(1): 53-57.
[5] Zhai Yan-qiang, Li Ke-zhi, Li He-jun, et al. Effects of NaF treatment on the bioactive apatite coating for C/C composites [J]. Acta Materiae Compositae Sinica,2007, 24(6): 89-94 (in Chinese).
[6] Cao Ning, Chen Hua-ying, Xue Cheng-qian, et al.Structure and strain rate effect of biomedical C/C composites [J]. Acta Materiae Compositae Sinica,2008, 25(6): 130-135 (in Chinese).
[7] Fu T, He L P, Han Y, et al. Induction of bonelike apatite on carbon-carbon composite by sodium silicate [J]. Materials Letters, 2003, 57(22-23): 3500-3503.
[8] ASTM F1088-04a, Standard specification for betatricalcium phosphate for surgical implantation [S].
[9] Carpenter D O. Effects of metals on the nervous system of humans and animals [J]. International Journal of Occupational Medicine & Environmental Health,2001, 14(3): 209-2181.
[10] Tamai N, Myoui A, Tomita T, et al. Novel hydroxyapatite ceramics with an interconnective porous structure exhibit superior osteoconduction in vivo [J].Journal of Biomedical Materials Research, 2002, 59(1):110-117.
[11] Lu W W, Zhao F, Luk K D K, et al. Controllable porosity hydroxyapatite ceramics as spine cage: Fabrication and properties evaluation [J]. Journal of Materials Science: Materials in Medicine, 2003, 14: 1039-1046.
[12] Zhang Ya-ni, Xu Yong-dong, Gao Lie-yi, et al. Microstructural evolution of phenolic resin-based carbon/carbon composites during pyrolysis [J]. Acta Materiae Compositae Sinica, 2006, 23(1): 37-43 (in Chinese).