Journal of Shanghai Jiao Tong University (Science) ›› 2019, Vol. 24 ›› Issue (6): 716-722.doi: 10.1007/s12204-019-2134-y

• • 上一篇    下一篇

Neural Firing Mechanism Underlying Two-Electrode Discrimination by 3D Transcutaneous Electrical Nerve Stimulation Computational Model

YE Shuan (叶栓), ZHU Kaihua (祝凯华), LI Peng (李鹏), SUI Xiaohong (隋晓红)   

  1. (School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China)
  • 出版日期:2019-12-15 发布日期:2019-12-07
  • 通讯作者: SUI Xiaohong (隋晓红) E-mail:suixhong@sjtu.edu.cn

Neural Firing Mechanism Underlying Two-Electrode Discrimination by 3D Transcutaneous Electrical Nerve Stimulation Computational Model

YE Shuan (叶栓), ZHU Kaihua (祝凯华), LI Peng (李鹏), SUI Xiaohong (隋晓红)   

  1. (School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China)
  • Online:2019-12-15 Published:2019-12-07
  • Contact: SUI Xiaohong (隋晓红) E-mail:suixhong@sjtu.edu.cn

摘要: Transcutaneous electrical nerve stimulation (TENS) has been widely used for sensory feedback which is a key consideration of improving the performance of prosthetic hands. Two-electrode discriminability is the key to realize high-spatial-resolution TENS, but the neural firing mechanism is not clear yet. The goal of this research is to investigate the neural firing patterns under two-electrode stimulation and to reveal the potential mechanisms. A three-dimensional (3D) model is established by incorporating Aβ fiber neuron clusters into a layered forearm structure. The diameters of the stimulating electrodes are selected as 5, 7, 9 and 12 mm, and the two-electrode discrimination distance (TEDD) is quantified. It is found that a distant TEDD is obtained for a relatively large electrode size, and 7mm is suggested to be the optimal diameter of stimulating electrodes. The present study reveals the neural firing patterns under two-electrode stimulation by the 3D TENS model. In order to discriminate individual electrodes under simultaneous stimulation, no crosstalk of activated Aβ fibers exists between two electrodes. This research can further guide the optimization of the electrode-array floorplan.

关键词: transcutaneous electrical nerve stimulation (TENS), computational model, artificial tactile sensation, two-electrode discrimination distance (TEDD)

Abstract: Transcutaneous electrical nerve stimulation (TENS) has been widely used for sensory feedback which is a key consideration of improving the performance of prosthetic hands. Two-electrode discriminability is the key to realize high-spatial-resolution TENS, but the neural firing mechanism is not clear yet. The goal of this research is to investigate the neural firing patterns under two-electrode stimulation and to reveal the potential mechanisms. A three-dimensional (3D) model is established by incorporating Aβ fiber neuron clusters into a layered forearm structure. The diameters of the stimulating electrodes are selected as 5, 7, 9 and 12 mm, and the two-electrode discrimination distance (TEDD) is quantified. It is found that a distant TEDD is obtained for a relatively large electrode size, and 7mm is suggested to be the optimal diameter of stimulating electrodes. The present study reveals the neural firing patterns under two-electrode stimulation by the 3D TENS model. In order to discriminate individual electrodes under simultaneous stimulation, no crosstalk of activated Aβ fibers exists between two electrodes. This research can further guide the optimization of the electrode-array floorplan.

中图分类号: