上海交通大学学报(英文版) ›› 2014, Vol. 19 ›› Issue (6): 702-705.doi: 10.1007/s12204-014-1569-4
ZENG Bao-yu (曾宝玉), BAI Jing-feng*(白景峰)
出版日期:
2014-12-31
发布日期:
2014-12-08
通讯作者:
BAI Jing-feng (白景峰)
E-mail:jfbai@sjtu.edu.cn
ZENG Bao-yu (曾宝玉), BAI Jing-feng*(白景峰)
Online:
2014-12-31
Published:
2014-12-08
Contact:
BAI Jing-feng (白景峰)
E-mail:jfbai@sjtu.edu.cn
摘要: Multiple wavelet hypothesis and fibrillatory conduction are believed to be atrial fibrillation’s pathogenesis. Radio frequency ablation (RFA) technique, a therapy for atrial fibrillation (AF), applies radio frequency (RF) energy to targeted tissue to make it transmural. Research on AF ablation has already been conducted in China. Currently, there are single-electrode and dual-electrode ablation electrodes. It is discovered that the latter can reduce the treatment time and maintain the ablation shape of the tissue. Clinical application has shown that it has become the first-line treatment option for part of indications patients with AF.
中图分类号:
ZENG Bao-yu (曾宝玉), BAI Jing-feng*(白景峰). Recent Advances in Radio Frequency Ablation Techniques of Atrial Fibrillation[J]. 上海交通大学学报(英文版), 2014, 19(6): 702-705.
ZENG Bao-yu (曾宝玉), BAI Jing-feng*(白景峰). Recent Advances in Radio Frequency Ablation Techniques of Atrial Fibrillation[J]. Journal of shanghai Jiaotong University (Science), 2014, 19(6): 702-705.
[1] Kazi D S, Hlatky M A. Atrial fibrillation ablation,symptoms, and stroke risk: Comment on discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation [J]. JAMA Internal Medicine, 2013, 173(2):156-157. [2] Cappato R, Calkins H, Chen S A, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation [J].Circulation: Arrhythmia and Electrophysiology, 2010,3(1): 32-38. [3] Tracy C M, Epstein A E, Darbar D, et al. 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities[J]. Heart Rhythm, 2012, 9(10): 1737-1753. [4] Zeng Rui, Zeng Zhi. The 2012 ESC interpretation and inspiration of valvular heart disease treatment guidelines [J]. Chinese Journal of Internal Medicine, 33(4):293-295 (in Chinese). [5] Zhou Zi-qiang, Hu Da-yi, Chen Jie, et al. Epidemiological studies of Chinese atrial fibrillation current situation [J]. Journal of Internal Medicine, 2004, 43(7):491-494 (in Chinese). [6] Du Xin, Ma Chang-sheng. Recognition of atrial fibrillation (A) [J]. Chinese Journal of Cardiovascular Disease Research, 2005, 3(10): 725-727 (in Chinese). [7] Tong Xin. Atrial fibrillation increases the risk of stroke [J]. Chinese Health Care, 2013(7): 38-39 (in Chinese). [8] Healey J S, Connolly S J, Gold M R, et al. Subclinical atrial fibrillation and the risk of stroke [J]. New England Journal of Medicine, 2012, 366(2): 120-129. [9] Dewire J, Agarwal S, Khurram I K, et al. Safety and efficacy of atrial fibrillation ablation in young patients [J]. Journal of Atrial Fibrillation, 2013, 6(3):19-22. [10] Bunch T J, May H T, Bair T L, et al. Atrial fibrillation ablation patients have long-term stroke rates similar to patients without atrial fibrillation regardless of CHADS2 score [J]. Heart Rhythm, 2013, 10(9):1272-1277. [11] Beukema R J, Adiyaman A, Smit J J J, et al.Catheter ablation for atrial arrhythmia recurrence following surgical atrial fibrillation ablation [J]. European Heart Journal, 2013, 34(supl 1): P511. [12] Morillo C A, Verma A, Connolly S J. Should radiofrequency ablation be first-line treatment for paroxysmal atrial fibrillation? [J]. The Journal of Clinical Outcomes Management, 2014, 21(4): 151-153. [13] Cao Yu-min. Pathogenesis of atrial fibrillation [J].China Coal Industry Medicine, 2011, 14(3): 460-461(in Chinese). [14] Liu Hong-qi. Advances in the pathogenesis and treatment of atrial fibrillation [J]. Hebei Medicine, 2009.31(20): 2793-2793 (in Chinese). [15] Jalife J. Mechanisms of persistent atrial fibrillation [J]. Current Opinion in Cardiology, 2014, 29(1): 20-27. [16] Haissaguerre M, Hocini M, Sanders P, et al. Catheter ablation of long-lasting persistent atrial fibrillation:Clinical outcome and mechanisms of subsequent arrhythmias [J]. Journal of Cardiovascular Electrophysiology,2005, 16(11): 1138-1147. [17] Bai Jing-feng, Chen Ya-zhu, Chen Chang-zhi, et al.Research of radiofrequency ablation instrument to cure atrial fibrillation [J]. Journal of Scientific Instrument,2006, 27(3): 259-262 (in Chinese). [18] Feng Jie. Thermal damage calculation and experimental study of radiofrequency ablation of atrial fibrillation therapy [D]. Shanghai: School of Biomedical Engineering,Shanghai Jiao Tong University, 2007 (in Chinese). [19] Ye Hong-yu, Huang Wei-zhao, Wu Ying-meng, et al. Compare the efficacy and safety of monopolar and bipolar radiofrequency ablation for atrial fibrillation during intraoperative [J]. Practical Journal of Medicine, 2013, 29(1): 75-77 (in Chinese). [20] Gillinov A M, Mccarthy P M. Atricure bipolar radiofrequency clamp for intraoperative ablation of atrial fibrillation [J]. The Annals of Thoracic Surgery, 2002,74(6): 2165-2168. [21] Huang W, Wu Y, Ye H, et al. Comparison of the outcomes of monopolar and bipolar radiofrequency ablation in surgical treatment of atrial fibrillation [J]. Chinese Medical Sciences Journal, 2014, 29(1): 28-32. [22] Kiser A C, Pappas H R, Garner K C, et al. Evaluation of an integrated bipolar and unipolar ablation device [J]. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2014, 9(1): 33-37. [23] Sivagangabalan G, Barry M A, Huang K, et al.Bipolar ablation of the interventricular septum is more efficient at creating a transmural line than sequential unipolar ablation [J]. Pacing and Clinical Electrophysiology,2010, 33(1): 16-26. [24] Nagashima K, Watanabe I, Okumura Y, et al. Epicardial ablation with irrigated electrodes: Effect of bipolar vs. unipolar ablation on lesion formation [J].Circulation Journal: Official Journal of the Japanese Circulation Society, 2011, 76(2): 322-327. [25] Gizurarson S, Spears D, Sivagangabalan G, et al. Bipolar ablation for deep intra-myocardial circuits: Human ex vivo development and in vivo experience [J].Europace, 2014: euu001. [26] Huang Zhi-hua, Li Ping, Liu Guang-jiao, et al. Efficacy of radiofrequency catheter ablation treatment of elderly patients with persistent atrial fibrillation [J].Chinese Journal of Gerontology, 2013, 33(015): 3571-3573 (in Chinese). [27] Ouyang F, Tilz R, Chun J, et al. Long-term results of catheter ablation in paroxysmal atrial fibrillation lessons from a 5-year follow-up [J]. Circulation, 2010,122(23): 2368-2377. |
[1] | ARRANZ Javier, GUO Jinyao, YU Xiao, WANG Jiaojiao, CHAI Xinyu, WANG Jiguang, SUI Xiaohong . Intrafascicular Vagal Activity Recording and Analysis Based on Carbon Nanotube Yarn Electrodes[J]. Journal of Shanghai Jiao Tong University(Science), 2020, 25(4): 447-452. |
[2] | YE Shuan (叶栓), ZHU Kaihua (祝凯华), LI Peng (李鹏), SUI Xiaohong (隋晓红). Neural Firing Mechanism Underlying Two-Electrode Discrimination by 3D Transcutaneous Electrical Nerve Stimulation Computational Model[J]. Journal of Shanghai Jiao Tong University (Science), 2019, 24(6): 716-722. |
[3] | MA Guohong1* (马国红), SHEN Xu1 (沈旭), PING Qiwen1 (平齐文),NIE Jun1 (聂军), YE Jia2 (叶佳). Microscopic Structure and Property of Double-Electrode Gas Metal Arc Welding of AZ31B Magnesium Alloy[J]. 上海交通大学学报(英文版), 2017, 22(3): 286-290. |
[4] | YANG Qing-zhao (杨青照), ZHOU Ming* (周明), TIAN Hong-sen (田洪森),ZHANG Hui-sheng (张惠生). Simulation of Adaptive Control Strategy for Electrical Discharge Machining Process[J]. 上海交通大学学报(英文版), 2015, 20(4): 408-414. |
[5] | WANG Shuan-yuan (王双园), GONG Liang* (贡亮), LIU Cheng-liang (刘成良). Self-Organizing Map Based Quality Assessment for Resistance Spot Welding with Featured Electrode Displacement Signals[J]. 上海交通大学学报(英文版), 2012, 17(6): 673-678. |
[6] | SUI Xiao-hong (隋晓红), . In-Vitro and In-Vivo Electrical Characteristics of a Penetrating Microelectrode Array for Optic Nerve Electrical Stimulation[J]. 上海交通大学学报(英文版), 2011, 16(5): 614-619. |
阅读次数 | ||||||||||||||||||||||||||||||||||||||||||||||||||
全文 202
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||
摘要 603
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||