上海交通大学学报(英文版) ›› 2014, Vol. 19 ›› Issue (2): 199-204.doi: 10.1007/s12204-014-1490-x

• • 上一篇    下一篇

PSCAD Based Multi-infeed HVDC System Simulation Validated by a Recorded Fault

ZHANG Xiao-hu* (张啸虎), BAI Jia-lin (白加林), CHEN Chen (陈 陈)   

  1. (School of Eletronics Information and Electrical Engnieering, Shanghai Jiaotong University, Shanghai 200240, China)
  • 出版日期:2014-04-30 发布日期:2014-04-29
  • 通讯作者: ZHANG Xiao-hu(张啸虎) E-mail: yxzxh@aliyun.com

PSCAD Based Multi-infeed HVDC System Simulation Validated by a Recorded Fault

ZHANG Xiao-hu* (张啸虎), BAI Jia-lin (白加林), CHEN Chen (陈 陈)   

  1. (School of Eletronics Information and Electrical Engnieering, Shanghai Jiaotong University, Shanghai 200240, China)
  • Online:2014-04-30 Published:2014-04-29
  • Contact: ZHANG Xiao-hu(张啸虎) E-mail: yxzxh@aliyun.com

摘要: More and more high voltage direct current (HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It’s large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current (AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current (MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current (PSCAD/EMTDC) system software package. Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.

关键词: multi-infeed high voltage direct current (HVDC), electromagnetic transient simulation, power system computer aided design/electro-magnetic transient in direct current (PSCAD/EMTDC) system, fault recorder

Abstract: More and more high voltage direct current (HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It’s large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current (AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current (MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current (PSCAD/EMTDC) system software package. Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.

中图分类号: