上海交通大学学报(英文版) ›› 2012, Vol. 17 ›› Issue (1): 13-019.doi: 10.1007/s12204-012-1224-x

• 论文 • 上一篇    下一篇

Degradation of Selected Indoor Air Pollutants: Comparison Study of Photocatalytic, Ozone-Assisted Photocatalytic and  Amine Adsorption Processes

ZHAO Wen-chang (赵文昌),      CHENG Jin-ping(程金平),     CHEN Ying (陈   颖),     WANG Wen-hua  (王文华)   

  1. (School of Environmental Science and Engineering, Shanghai Jiaotong University, Shanghai 200240, China)
  • 收稿日期:2010-12-23 出版日期:2012-02-29 发布日期:2012-03-21
  • 通讯作者: WANG Wen-hua (王文华) E-mail: whwang@sjtu.edu.cn

Degradation of Selected Indoor Air Pollutants: Comparison Study of Photocatalytic, Ozone-Assisted Photocatalytic and  Amine Adsorption Processes

ZHAO Wen-chang (赵文昌),      CHENG Jin-ping(程金平),     CHEN Ying (陈   颖),     WANG Wen-hua  (王文华)   

  1. (School of Environmental Science and Engineering, Shanghai Jiaotong University, Shanghai 200240, China)
  • Received:2010-12-23 Online:2012-02-29 Published:2012-03-21
  • Contact: WANG Wen-hua (王文华) E-mail: whwang@sjtu.edu.cn

摘要: Abstract: Indoor air pollutants impact human
health, comfort and productivity. The method of photocatalysis has
been applied mainly in flow reactors and little information is
available on indoor air pollutant removal in airtight reactors. In
the paper, experiments were carried out to remove formaldehyde
(HCHO), ammonia (NH_3) and volatile organic compounds (VOCs) in
the airtight and ventilated chambers. Results demonstrated that
90.4% of HCHO, 92.3% of NH_3 and 57.9% of VOCs were
removed in the amine adsorption process, while 67.5%
(hereinbefore, these are the mass fraction) of HCHO, 60.0% of
NH_3, and 61.2% of VOCs were removed in the photocatalytic
process. However, ozone-assisted photocatalytic process showed great
potential to degrade indoor air pollutants in the ventilated
chamber. Factors and mechanisms of the photocatalytic degradation of
HCHO, NH_3 and VOCs were also discussed.

关键词: TiO_2 photocatalysis, ozone-assisted photocatalysis, amine adsorption process, indoor air pollutants

Abstract: Abstract: Indoor air pollutants impact human
health, comfort and productivity. The method of photocatalysis has
been applied mainly in flow reactors and little information is
available on indoor air pollutant removal in airtight reactors. In
the paper, experiments were carried out to remove formaldehyde
(HCHO), ammonia (NH_3) and volatile organic compounds (VOCs) in
the airtight and ventilated chambers. Results demonstrated that
90.4% of HCHO, 92.3% of NH_3 and 57.9% of VOCs were
removed in the amine adsorption process, while 67.5%
(hereinbefore, these are the mass fraction) of HCHO, 60.0% of
NH_3, and 61.2% of VOCs were removed in the photocatalytic
process. However, ozone-assisted photocatalytic process showed great
potential to degrade indoor air pollutants in the ventilated
chamber. Factors and mechanisms of the photocatalytic degradation of