Optimal Selection Method for Low-Carbon Buildings for Peak-Shaving Demand Response

Expand
  • 1. College of Electrical Engineering, Zhejiang University, Hangzhou 310007, China; 2. Shenzhen Energy Group Co., Ltd., Shenzhen 518033, Guangdong, China; 3. Shenzhen Research Institute, Southeast University, Shenzhen 518057, Guangdong, China

Online published: 2026-10-11

Supported by

low-carbon building; peak-shaving demand response; evaluation index system; photovoltaic penetration rate; combined weighting; optimal selection

Abstract

With the implementation of policies and standards related to low-/zero-carbon buildings, guiding low-carbon buildings equipped with \"green\" regulation capabilities to participate in peak-shaving Demand Response (DR) to achieve high-quality interactions with the power grid is of great significance for supporting the low-carbon transition of industrial parks and power system. However, due to their highly integrated source-load-storage characteristics, low-carbon buildings face challenges when they participate in peak-shaving DR, including difficulties in determining load baselines, the time-varying nature of regulation capabilities, and the complexity of controlling response deviations. To address these issues, an evaluation index system and an optimal selection method for low-carbon buildings oriented towards peak-shaving DR are proposed. First, a three-level evaluation index system tailored for low-carbon buildings is constructed from the dimensions of baseline credibility, peak-shaving DR capability, and response deviation balancing capability. Second, a combined weighting and optimal selection strategy that accounts for both subjective and objective preferences is proposed, ensuring that the optimal ranking relies more heavily on the actual values of each evaluation index. Finally, four university buildings equipped with photovoltaic power generation facilities are taken as test cases, and the effectiveness of the proposed method is validated from the dimensions of multi-scenario applicability and scheme superiority. The results indicate that the proposed index system exhibits excellent interpretability and can accurately assess the DR potential of low-carbon buildings under different photovoltaic penetration rate scenarios. Furthermore, the proposed optimal selection method can provide decision-making support for industrial park operators to evaluate and efficiently screen high-quality DR buildings.

Cite this article

LIU Weifeng, LIAO Mei, DENG Wanli, WU Zaijun, FANG Yuchen, YE Chengjin . Optimal Selection Method for Low-Carbon Buildings for Peak-Shaving Demand Response[J]. Journal of Shanghai Jiaotong University, 0 : 1 . DOI: 10.16183/j.cnki.jsjtu.2026.241

Outlines

/

〈 〉