Estimation Method for Metal Damage Struck by Lightning Considering Probability Distribution of Lightning Current Parameters
Received date: 2019-04-23
Online published: 2020-12-31
Taking the commonly used metal material aluminum 3003 as an example, and based on the simulated lightning current metal damage test results in the four typical compositions of actual lightning current, the damage characterization parameters such as damage area and damage depth of aluminum 3003 alloy and lightning current parameters were analyzed. Taking the building as an example, and based on the parameter analysis of the combined probability distribution of lightning strike density, lightning interception area, lightning current amplitude and transferred charge amount, the annual average number of lightning strikes and the distribution characteristics of lightning current parameters of metal materials were calculated. A damage estimation method considering the probability distribution of lightning current parameters when a metal material with aluminum 3003 alloy and building carrier as an example was subjected to lightning strikes was established. The results show that the damage depth of the aluminum 3003 alloy material under the action of short-term first return current component and short-duration subsequent return current component is less than 0.1 mm, which can be ignored. The damage area of the aluminum 3003 alloy material is proportional to the magnitude of the lightning current suffered, and the damage depth of the alloy is proportional to the amount of charge transferred by the lightning current.
LI Tianwei, LIU Lei, CHEN Jian . Estimation Method for Metal Damage Struck by Lightning Considering Probability Distribution of Lightning Current Parameters[J]. Journal of Shanghai Jiaotong University, 2020 , 54(12) : 1252 -1258 . DOI: 10.16183/j.cnki.jsjtu.2019.115
[1] | 陈家宏,冯万兴,王海涛,等. 雷电参数统计方法[J]. 高电压技术,2007, 33(10): 6-10. |
[1] | CHEN Jiahong, FENG Wanxing, WANG Haitao, et al. Statistical method of lightning parameters[J]. High Voltage Engineering, 2007, 33(10): 6-10. |
[2] | LIU Y, DAI M, GUHA A, et al. Damage characteristics and microstructure response of steel alloy Q235B subjected to simulated lightning currents[J]. IEEE Access, 2019, 8(7): 9258-9264. |
[3] | 刘亚坤,夏海亮,何雨微,等. 雷击时金属油罐的损伤与温升特性[J]. 高电压技术,2016, 42(5): 1578-1585. |
[3] | LIU Yakun, XIA Hailiang, HE Yuwei, et al. Ablation damage and temperature rise of metal oil tanks struck by direct lightning[J]. High Voltage Engineering, 2016, 42(5): 1578-1585. |
[4] | 中华人民共和国住房和城乡建设部.建筑物防雷设计规范:GB 50057-2010[S]. 北京:中国计划出版社,2010. |
[4] | Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Design code for protection of structures against lightning: GB 50057-2010[S]. Beijing: China Planning Press, 2010. |
[5] | 夏海亮,刘亚坤,刘全桢,等. 长持续时间雷电流分量作用下电极形状对金属烧蚀特性的影响[J]. 上海交通大学学报,2017, 51(8): 903-908. |
[5] | XIA Hailiang, LIU Yakun, LIU Quanzhen, et al. Metal ablation affected by electrode shapes under long continuing lightning current[J]. Journal of Shanghai Jiao Tong University, 2017, 51(8): 903-908. |
[6] | 李瑞芳,吴广宁,曹晓斌,等. 雷电流幅值概率计算公式[J]. 电工技术学报,2011, 26(4): 161-167. |
[6] | LI Ruifang, WU Guangning, CAO Xiaobin, et al. Formula for probability of lightning current amplitude[J]. Transactions of China Electrotechnical Society, 2011, 26(4): 161-167. |
[7] | 黄晓虹,周歧斌,杜亚平. 分析带金属板结构的建筑物内部雷电脉冲磁场分布的等效电路法[J]. 上海交通大学学报,2012, 46(7): 1112-1116. |
[7] | HUANG Xiaohong, ZHOU Qibin, DU Yaping. An equivalent circuit method for computing lightning-induced magnetic fields in structures with metallic plates[J]. Journal of Shanghai Jiao Tong University, 2012, 46(7): 1112-1116. |
[8] | RAKOV V A, UMAN M A. Lightning physics and effects[M]. New York: Cambridge University Press, 2003. |
[9] | COORAY V. The lightning flash[M]. IET Digital Library, 2013. |
[10] | LIU Y K, FU Z C, GAO X, et al. Damage characteristics and response of Al alloy 3003 to different components of simulated lightning currents[J]. IEEE Access, 2018, 6: 1277-1283. |
[11] | HE J L, RAKOV V, WANG D H, et al. Lightning physics and effects[J]. Atmospheric Research, 2013, 129: 33-34. |
[12] | LIU Y K, FU Z C, LIU Q Z, et al. Numerical inversion analysis on front-face temperature rise of Al alloy suffered from long continuing current in lightning[J]. IET Science Measurement & Technology, 2018, 12(4): 467-471. |
[13] | CLIFFORD D W, CROUCH K E, SCHULTE E H. Lightning simulation and testing[J]. IEEE Transactions on Electromagnetic Compatibility, 1982, 24(2): 209-224. |
[14] | International Electrotechnical Commission. Protection against lightning Part 3: Physical damage to structures and life hazard[S]. Geneva: IEC, Geneva, 2010. |
[15] | SUN J R, YAO X L, XU W J, et al. Lightning test method for optical-fiber overhead ground wires[J]. IEEE Transactions on Power Delivery, 2018, 33(5): 2412-2419. |
[16] | 高磊,凌晨. 关于建筑物等效截收面积计算的若干问题探讨[J]. 气象科技,2014, 42(6): 1126-1130. |
[16] | GAO Lei, LING Chen. Problems encountered in calculating equivalent collection areas of structures[J]. Meteorological Science and Technology, 2014, 42(6): 1126-1130. |
[17] | LIU Y K, FU Z C, LIU Q Z, et al. Experimental and analytical investigation on metal damage suffered from simulated lightning currents[J]. Plasma Science & Technology, 2017, 19(12): 125301-125310. |
[18] | RAKOV V A, BORGHETTI A, BOUQUEGNEAU C, et al. CIGRE technical brochure on lightning parameters for engineering applications[C]∥2013 International Symposium on Lightning Protection (XII SIPDA). Piscataway, NJ, USA: IEEE, 2013: 373-377. |
/
〈 |
|
〉 |