Micromotion Simulation and Optimal Design of Multi-Shank Fish-Bone-Shaped Electrode

Expand
  • State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, China

Online published: 2019-05-28

Abstract

In order to improve the long-term effectiveness of neural electrode, kinetic analysis of the micromotion at the electrode-brain interface was conducted using finite element simulation method. Compared with the traditional commercial electrode, the fish-bone-shaped electrode shows great effectiveness in reducing the micromotion induced injury. Moreover, the influence of the number of electrode shanks on micromotion induced injury of brain tissue was revealed. Based on the rationality and optimization principles of electrode site distribution, a novel multi-shank fish-bone-shaped electrode was developed. The electrode decreases the maximum strain, von Mises stress and total deformation of brain tissue by 73.23%, 48.78% and 76.92% respectively compared with the original one. In addition, the novel electrode performs better than the commercial three-shank electrode with the same size and site distribution when both of the electrodes collect the same electrical signal. The results reveal that the novel electrode reduces the strain in the brain tissue considerably, and is expected to improve the lifetime of electrode effectively.

Cite this article

YIN Xuele,ZHANG Wenguang,TANG Jiaqi,YU Qian . Micromotion Simulation and Optimal Design of Multi-Shank Fish-Bone-Shaped Electrode[J]. Journal of Shanghai Jiaotong University, 2019 , 53(5) : 529 -534 . DOI: 10.16183/j.cnki.jsjtu.2019.05.003

References

[1]MINEV I R, MUSIENKO P, HIRSCH A, et al. Electronic dura mater for long-term multimodal neural interfaces[J]. Science, 2015, 347(6218): 159-163. [2]FERNNDEZ E, GREGER B, HOUSE P A, et al. Acute human brain responses to intracortical microelectrode arrays: Challenges and future prospects[J]. Frontiers in Neuroengineering, 2014, 7: 24. [3]ALBA N A, DU Z J, CATT K A, et al. In vivo electrochemical analysis of a PEDOT/MWCNT neural electrode coating[J]. Biosensors, 2015, 5(4): 618-646. [4]GUTOWSKI S M, TEMPLEMAN K L, SOUTH A B, et al. Host response to microgel coatings on neural electrodes implanted in the brain[J]. Journal of Biomedical Materials Research Part A, 2014, 102(5): 1486-1499. [5]吴栋栋, 张文光, MERCERON Gilles, 等. 神经电极-脑组织界面微动环境力学特性仿真[J]. 浙江大学学报(工学版), 2013, 47(2): 256-260. WU Dongdong, ZHANG Wenguang, MERCERON Gilles, et al. Mechanical simulation of neural electrode-brain tissue interface under different micro-motion conditions[J]. Journal of Zhejiang University (Engineering Science), 2013, 47(2): 256-260. [6]GILLETTI A, MUTHUSWAMY J. Brain micromotion around implants in the rodent somatosensory cortex[J]. Journal of Neural Engineering (Engineering Science), 2006, 3(3): 189-195. [7]ZHANG W G, WU D D, LI Z W, et al. Electrochemically synthesized PANI-MnO2 coatings and their effect on interface properties of neural microelectrode[J]. Journal of Functional Materials, 2014, 45(12): 155-162. [8]TOOKER A, TOLOSA V, SHAH K G, et al. Optimization of multi-layer metal neural probe design[C]//International Conference of the IEEE Engineering in Medicine and Biology Society. New York: IEEE, 2012: 5995-5998. [9]KUO J T, KIM B J, HARA S A, et al. Novel flexible parylene neural probe with 3D sheath structure for enhancing tissue integration[J]. Lab Chip, 2013, 13(4): 554-561. [10]WU F, IM M, YOON E. A flexible fish-bone-shaped neural probe strengthened by biodegradable silk coating for enhanced biocompatibility[C]//Solid-State Sensors, Actuators and Microsystems Conference. New York: IEEE, 2011: 966-969. [11]HAMZAVI N, TSANG W M, SHIM V P W. Nonlinear elastic brain tissue model for neural probe-tissue mechanical interaction[C]//International IEEE/EMBS Conference on Neural Engineering. San Diego: IEEE, 2013: 1119-1122. [12]RASHID B, DESTRADE M, GILCHRIST M D. Hyperelastic and viscoelastic properties of brain tissue in tension[C]//ASME 2012 International Mechanical Engineering Congress and Exposition. New York: ASME, 2012: 921-929. [13]SEYMOUR J P, KIPKE D R. Fabrication of polymer neural probes with sub-cellular features for reduced tissue encapsulation[C]// International Conference of the IEEE Engineering in Medicine and Biology Society. New York: IEEE, 2006: 4606-4609. [14]MERRIAM M E. A three-dimensional bidirectional interface for neural mapping studies[D]. Michigan: University of Michigan, 2010. [15]EATON K P, HENRIQUEZ C S. Confounded spikes generated by synchrony within neural tissue models[J]. Neurocomputing, 2005, 65/66: 851-857. [16]POLIKOV V S, TRESCO P A, REICHERT W M. Response of brain tissue to chronically implanted neural electrodes[J]. Journal of Neuroscience Methods, 2005, 148(1): 1-18.
Outlines

/