In order to attest the validity of neural electrode with the capability of micro-motion attenuation, comparative studies based on evaluation system for testing tissue injury were conducted. Different implantation parameters (depth: 1.5, 3, 4.5mm; insertion speed: 50, 100, 500, 1000, 1500, 2000μm/s) were set respectively for the experiment with the micro-motion attenuation electrode and the common electrode to study the affects of the two electrodes. This method is controlable, and can effectly avoid the uncertainty of vivo experiments. The conclusion was found that the modified electrode is not better than the reference electrode at the depth of 1.5mm. But it has obvious advantage on decreasing the tissue injury when the insertion depths are 3mm and 4.5mm.
TANG Jiaqi,ZHANG Wenguang,CAI Fenglong,YIN Xuele
. A Comparative Study on Tissue Injury Caused by Implantation Based on
Electrode with the Capability of Micro-Motion Attenuation[J]. Journal of Shanghai Jiaotong University, 2018
, 52(2)
: 188
-193
.
DOI: 10.16183/j.cnki.jsjtu.2018.02.010
[1]OLUIGBO C O, REZAI A R. Addressing neurological disorders with neuromodulation[J]. IEEE Transactions on Biomedical Engineering, 2011, 58(7): 1907-1917.
[2]MINEV I R, MUSIENKO P, HIRSCH A, et al. Electronic dura mater for long-term multimodal neural interfaces[J]. Science, 2015, 347(6218): 159-163.
[3]STREIT W, XUE Q S, PRASAD A, et al. Electrode failure: Tissue, electrical, and material responses[J]. IEEE Pulse, 2012, 3(1): 30-33.
[4]FERNNDEZ E, GREGER B, HOUSE P A, et al. Acute human brain responses to intracortical microelectrode arrays: Challenges and future prospects[J].Frontiers in Neuroengineering, 2014, 7: 24.
[5]ZHU R, HUANG G L, YOON H, et al. Biomechanical strain analysis at the interface of brain and nanowire electrodes on a neural probe[J]. Chemischer Informationsdienst, 2011, 2(29): 31001-31006.
[6]PAULO C, PRATAS J. A response surface model predicting the in vivo insertion behavior of micro-machined neural implants[J]. Journal of Neural Engineering, 2011, 9(1): 016005.
[7]BJORNSSON C S, OH S J, AL-KOFAHI Y A, et al. Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion[J]. Journal of Neural Engineering, 2006, 3(3): 196-207.
[8]KONTORINIS G, LENARZ T, STVER T, et al. Impact of the insertion speed of cochlear implant electrodes on the insertion forces[J]. Otology & Neurotology, 2011, 32(4): 565-570.
[9]ZHANG W G, MA Y K, LI Z W. Experimental evaluation of neural probe’s insertion induced injury based on digital image correlation method[J]. Medical Physics, 2016, 43(1): 505-512.
[10]SEYMOUR J P, KIPKE D R. Neural probe design for reduced tissue encapsulation in CNS[J]. Biomaterials, 2007, 28(25): 3594-3607.
[11]李正伟, 马亚坤, 张文光. 基于柔顺机构的减振神经电极的设计与评估[J]. 上海交通大学学报, 2015, 49(12): 1888-1892.
LI Zhengwei, MA Yakun, ZHANG Wenguang. Physical design concepts and biomechanical evaluations of a novel neural electrode abutment with micromotion-attenuation capability based on compliant mechanisms [J]. Journal of Shanghai Jiao Tong University, 2015, 49(12): 1888-1892.
[12]PAN B, LU Z X, XIE H M. Mean intensity gradient: An effective global parameter for quality assessment of the speckle patterns used in digital image correlation[J]. Optics and Lasers in Engineering, 2010, 48(4): 469-477.
[13]WELKENHUYSEN M, ANDREI A, AMEYE L, et al. Effect of insertion speed on tissue response and insertion mechanics of a chronically implanted silicon-based neural probe[J]. IEEE Transactions on Biome-dical Engineering, 2011, 58(11): 3250-3259.
[14]PINTO J M T, TOUCHARD F, CASTAGNET S, et al. DIC strain measurements at the micro-scale in a semi-crystalline polymer[J]. Experimental Mechanics, 2013, 53(8): 1311-1321.
[15]JR S S, KHALIFA Y M, BUCKLEY M R. The location-and depth-dependent mechanical response of the human cornea under shear loading[J]. Investigative Ophthalmology & Visual Science, 2014, 55(12): 7919-7924.