Positron emission tomography - computed tomography (PET/CT) is an advanced molecular imaging technique that is mainly used for the early detection and diagnosis of major heart diseases and tumors. To reduce imaging artifacts caused by the patient's respiratory motion, the mainstream respiratory control method such as gating technique has been widely used. Based on the optical fiber pressure sensor, a real-time analysis software system of respiratory motion information has been developed in this study. A gate alignment algorithm for correlating respiratory motion in PET/CT scanning was investigated. In this study, a real-time extraction algorithm of smooth respiratory waveform and a fast temporal phase segmentation algorithm were proposed, reducing the computational complexity and guaranteeing low latency and high recognition accuracy, and then they were implemented in the lower computer by programming. The software and hardware integration of the respiratory acquisition system with the fiber-optic sensor-based mattress was realized, and the whole prototype product was developed for experimental studies. Compared with the existing traditional methods, the average detection latency of the method in this study is less than 150 ms (about 300 ms for existing methods), and the relative error of temporal phase segmentation is about 1% (about 5% for existing methods). This study offers significant potential for enhancing PET/CT imaging quality and efficiency, with future steps aimed at integrating the system into commercial platforms for clinical validation.
MAO Yuxuan, LIU Weiping, CHEN Xiaojun
. Information Analysis System of Human Respiratory Motion for PET/CT Scanning[J]. Journal of Shanghai Jiaotong University(Science), 2026
, 31(5)
: 1374
-1385
.
DOI: 10.1007/s12204-025-2833-5
[1] FERLAY J, SOERJOMATARAM I, DIKSHIT R, et al. Cancer incidence and mortality worldwide: Sources, methods and major patterns in GLOBOCAN 2012 [J]. International Journal of Cancer, 2015, 136(5): E359-E386.
[2] FIDLER M M, GUPTA S, SOERJOMATARAM I, et al. Cancer incidence and mortality among young adults aged 20–39 years worldwide in 2012: A population-based study [J]. The Lancet Oncology, 2017, 18(12): 1579-1589.
[3] BEN-HAIM S, ELL P. 18F-FDG PET and PET/CT in the evaluation of cancer treatment response [J]. Journal of Nuclear Medicine, 2009, 50(1): 88-99.
[4] SATOH Y, MOTOSUGI U, IMAI M, et al. Comparison of dedicated breast positron emission tomography and whole-body positron emission tomography/computed tomography images: A common phantom study [J]. Annals of Nuclear Medicine, 2020, 34(2): 119-127.
[5] BERG E, CHERRY S R. Innovations in instrumentation for positron emission tomography [J]. Seminars in Nuclear Medicine, 2018, 48(4): 311-331.
[6] TOWNSEND D W. Dual-modality imaging: Combining anatomy and function [J]. Journal of Nuclear Medicine, 2008, 49(6): 938-955.
[7] SPENCER B A, BERG E, SCHMALL J P, et al. Performance evaluation of the uEXPLORER total-body PET/CT scanner based on NEMA NU 2-2018 with additional tests to characterize PET scanners with a long axial field of view [J]. Journal of Nuclear Medicine, 2021, 62(6): 861-870.
[8] DAOU D. Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35(11): 1961-1970.
[9] VISVIKIS D, LAMARE F, BRUYANT P, et al. Respiratory motion in positron emission tomography for oncology applications: Problems and solutions [J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006, 569(2): 453-457.
[10] ZENG C, LI X, LU W, et al. Accuracy and efficiency of respiratory gating comparable to deep inspiration breath hold for pancreatic cancer treatment [J]. Journal of Applied Clinical Medical Physics, 2021, 22(1): 218-225.
[11] GRECO C, ROSENZWEIG K, CASCINI G L, et al. Current status of PET/CT for tumour volume definition in radiotherapy treatment planning for non-small cell lung cancer (NSCLC) [J]. Lung Cancer, 2007, 57(2): 125-134.
[12] GROOTJANS W, TIXIER F, VAN DER VOS C S, et al. The impact of optimal respiratory gating and image noise on evaluation of intratumor heterogeneity on 18F-FDG PET imaging of lung cancer [J]. Journal of Nuclear Medicine, 2016, 57(11): 1692-1698.
[13] KEALL P J, MAGERAS G S, BALTER J M, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J]. Medical Physics, 2006, 33(10): 3874-3900.
[14] ZHAO R J, DU L D, ZHAO Z, et al. Accurate estimation of heart and respiration rates based on an optical fiber sensor using adaptive regulations and statistical classifications spectrum analysis [J]. Frontiers in Digital Health, 2021, 3: 747460.
[15] ZHANG Y J. Research on non-contact vital sign signal processing method based on empirical pattern decomposition [D]. Nanjing: Nanjing University of Science and Technology, 2015 (in Chinese).
[16] LIU S P, GAO R X, JOHN D, et al. Tissue artifact removal from respiratory signals based on empirical mode decomposition [J]. Annals of Biomedical Engineering, 2013, 41(5): 1003-1015.
[17] SHIN H S, LEE C, LEE M. Adaptive threshold method for the peak detection of photoplethysmographic waveform [J]. Computers in Biology and Medicine, 2009, 39(12): 1145-1152.
[18] SHARP G C, JIANG S B, SHIMIZU S, et al. Prediction of respiratory tumour motion for real-time image-guided radiotherapy [J]. Physics in Medicine & Biology, 2004, 49(3): 425.
[19] KALET A, SANDISON G, WU H M, et al. A state-based probabilistic model for tumor respiratory motion prediction [J]. Physics in Medicine & Biology, 2010, 55(24): 7615.
[20] RIAZ N, SHANKER P, WIERSMA R, et al. Predicting respiratory tumor motion with multi-dimensional adaptive filters and support vector regression [J]. Physics in Medicine and Biology, 2009, 54(19): 5735-5748.
[21] VEDAM S S, KEALL P J, DOCEF A, et al. Predicting respiratory motion for four-dimensional radiotherapy [J]. Medical Physics, 2004, 31(8): 2274-2283.
[22] RUAN D, FESSLER J A, BALTER J M. Real-time prediction of respiratory motion based on local regression methods [J]. Physics in Medicine and Biology, 2007, 52(23): 7137-7152.
[23] REMY C, AHUMADA D, LABINE A, et al. Potential of a probabilistic framework for target prediction from surrogate respiratory motion during lung radiotherapy [J]. Physics in Medicine & Biology, 2021, 66(10): 105002.