In the process of external radiation therapy, eye movements need to be detected in real time using an eye tracking system. The complex eye tracking system may interfere with the treatment radiation beam, so it is necessary to build a system model to detect possible interference and ensure that the input dose to the diseased site is as expected. Firstly, the scene needs to be modeled, and the control robotic arm and its end structure are modeled using the Denavit-Hartenberg (D-H) parameters. The interference detection is implemented using the Gilbert-Johnson-Keerthi algorithm and the detection results are displayed using the Godot Engine, while the simulation scene built in Simscape using the same model is compared and verified. The results of the two simulations are compared under the condition that the robot arm is in the initial position, and the incident rays are at different angles, respectively, proving the effectiveness of the D-H parametric modeling and the interference detection algorithm.
LUO Jiachen, SHI Dequan, WANG Xu, WANG Kundong
. Interference Detection Method for Eye Tracking System in External Radiation Therapy[J]. Journal of Shanghai Jiaotong University(Science), 2026
, 31(5)
: 1366
-1373
.
DOI: 10.1007/s12204-024-2753-9
[1] FINGER P T. Radiation therapy for choroidal melanoma [J]. Survey of Ophthalmology, 1997, 42(3): 215-232.
[2] GRAGOUDAS E S. Proton beam irradiation of uveal melanomas: The first 30 years. The Weisenfeld Lecture [J]. Investigative Ophthalmology & Visual Science, 2006, 47(11): 4666-4673.
[3] VIA R, PELLA A, ROMANÒ F, et al. A platform for patient positioning and motion monitoring in ocular proton therapy with a non-dedicated beamline [J]. Physica Medica, 2019, 59: 55-63.
[4] VIA R, FASSI A, FATTORI G, et al. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy [J]. Medical Physics, 2015, 42(5): 2194-2202.
[5] ELISEI G, PELLA A, RICOTTI R, et al. Development and validation of a new set-up simulator dedicated to ocular proton therapy at CNAO [J]. Physica Medica, 2021, 82: 228-239.
[6] VIA R, PICA A, ANTONIOLI L, et al. MRI and FUNDUS image fusion for improved ocular biometry in Ocular Proton Therapy [J]. Radiotherapy and Oncology, 2022, 174: 16-22.
[7] VIA R, HENNINGS F, FATTORI G, et al. Noninvasive eye localization in ocular proton therapy through optical eye tracking: A proof of concept [J]. Medical Physics, 2018, 45(5): 2186-2194.
[8] CIOCCA M, MAGRO G, MASTELLA E, et al. Design and commissioning of the non-dedicated scanning proton beamline for ocular treatment at the synchrotron-based CNAO facility [J]. Medical Physics, 2019, 46(4): 1852-1862.
[9] VIA R, HENNINGS F, FATTORI G, et al. Technical Note: Benchmarking automated eye tracking and human detection for motion monitoring in ocular proton therapy [J]. Medical Physics, 2020, 47(5): 2237-2241.
[10] SECIL S, OZKAN M. Minimum distance calculation using skeletal tracking for safe human-robot interaction [J]. Robotics and Computer-Integrated Manufacturing, 2022, 73: 102253.
[11] WU C Z, YUE Y, WEI B C, et al. Self-collision detection and motion planning for dual-arm robot [J]. Journal of Shanghai Jiao Tong University, 2018, 52(1): 45-53 (in Chinese).
[12] HUESO-GONZÁLEZ F, WOHLFAHRT P, CRAFT D, et al. An open-source platform for interactive collision prevention in photon and particle beam therapy treatment planning [J]. Biomedical Physics & Engineering Express, 2020, 6(5): 055013.
[13] YU V Y, TRAN A, NGUYEN D, et al. The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery [J]. Medical Physics, 2015, 42(11): 6457-6467.
[14] SURIYAKUMAR V M, XU R, PINTER C, et al. Open-source software for collision detection in external beam radiation therapy [J]. Proceedings of SPIE, 2017, 10135: 101351G.
[15] WEI X Y, LIU M H, LING Z, et al. Approximate convex decomposition for 3D meshes with collision-aware concavity and tree search [J]. ACM Transactions on Graphics, 2022, 41(4): 42.