Engineering & Al for Health

Structural Design of Implant Fusion Based on Triple Period Minimal Surface and Its Performance Analysis

Expand
  • School of Mechanical Engineering, Xinjiang University, Urumqi 830017, China; 2. Sixth Affiliated Hospital, Xinjiang Medical University, Urumqi 830000, China

Received date: 2024-09-18

  Accepted date: 2024-12-27

  Online published: 2025-04-28

Abstract

Porous structures of triple periodic minimal surface (TPMS) based on diamond (D), gyroid (G), and primitive (P) have become a leading choice in dental implant design because of their excellent mechanical and biological characteristics. However, the natural mandibular tissue is inherently heterogeneous, and using homogeneous porous implants might cause pathological bone stress concentrations. To address this issue, this study constructs a TPMS implant with an axially fused structure based on the Sigmoid function and parametric design. The fused structure axially integrates two types of TPMS units. A simulation analysis for 18 different structures was conducted to analyze the differences between fused structures (D-G, D-P, and G-P) and homogeneous structures (D, G, P) under constant porosities of 50%, 60%, and 70% in terms of equivalent elastic modulus, equivalent yield strength, permeability, fluid wall shear stress, and micromotion at the implant-bone interface. The results show that compared with the homogeneous scaffolds, the fusion structure (D-G) has a low and wide range of elastic modulus, which decreases from 12.23 GPa to 4.58 GPa in a porosity range of 50%—70%, and its elastic modulus range increases by 28% on average. The yield strength was similar to that of cortical bone. The permeability was lower than that of the homogeneous scaffold (G, P), but it met the requirements of natural bone. In terms of fluid shear stress, the average wall shear stress of the fusion structure (D-G) was greater than that of the homogeneous structure, and its suitable growth zone accounted for 98.9%. In the simulation of implant-bone interface fretting under the effect of the occluding force, the axial fusion structure (D-G) showed a stress distribution more similar to that of the mandible; that is, a larger stress distribution was in the upper D structure region in contact with cortical bone, and a smaller stress was evenly distributed in the lower G structure region in contact with cancellous bone. This stress distribution effectively reduces the difference in stress and microstrain between cortical bone and cancellous bone, avoids the phenomenon of stress concentration in cancellous bone, reduces the risk of bone resorption, and improves the overall biomechanical stability of the implant.

Cite this article

LI Haijie, HAI Jizhe, SHAN Chunlong, XU Qingyu, XU Zhiguo, LEI Yueheng, JING Lei . Structural Design of Implant Fusion Based on Triple Period Minimal Surface and Its Performance Analysis[J]. Journal of Shanghai Jiaotong University(Science), 2026 , 31(5) : 1197 -1212 . DOI: 10.1007/s12204-025-2822-8

References

[1] ZHOU J, GUI Y Q, XU Q P, et al. Investigation of permeability and biocompatibility of TPMS structures printed by laser powder bed fusion using Ti64-5Cu alloy for orthopedic implants [J]. Materials Letters, 2024, 355: 135552.
[2] SHI Z A, ZHOU X. The bionic bone scaffold structure design based on the triply periodic minimal surface modeling method [J]. Machinery, 2020, 47(3): 1-6 (in Chinese).
[3] DENG Z B, ZHOU C C, FAN Y J, et al. Design and characterization of porous titanium scaffold for bone tissue engineering [J]. Rare Metal Materials and Engineering, 2016, 45(9): 2287-2292 (in Chinese).
[4] GÜNTHER F, WAGNER M, PILZ S, et al. Design procedure for triply periodic minimal surface based biomimetic scaffolds [J]. Journal of the Mechanical Behavior of Biomedical Materials, 2022, 126: 104871.
[5] LI L, WANG P, LIANG H X, et al. Design of a Haversian system-like gradient porous scaffold based on triply periodic minimal surfaces for promoting bone regeneration [J]. Journal of Advanced Research, 2023, 54: 89-104.
[6] REZAPOURIAN M, KAMBOJ N, JASIUK I, et al. Biomimetic design of implants for long bone critical-sized defects [J]. Journal of the Mechanical Behavior of Biomedical Materials, 2022, 134: 105370.
[7] VIET N V, WAHEED W, ALAZZAM A, et al. Effective compressive behavior of functionally graded TPMS titanium implants with ingrown cortical or trabecular bone [J]. Composite Structures, 2023, 303: 116288.
[8] YE J H, HE W H, WEI T P, et al. Mechanical properties directionality and permeability of fused triply periodic minimal surface porous scaffolds fabricated by selective laser melting [J]. ACS Biomaterials Science & Engineering, 2023, 9(8): 5084-5096.
[9] ZENG S J, HE W H, WANG J, et al. Structural design and mechanical properties analysis of fused triply periodic minimal surface porous scaffold [J]. Journal of Materials Engineering and Performance, 2023, 32(9): 4083-4096.
[10] ARABNEJAD S, BURNETT JOHNSTON R, PURA J A, et al. High-strength porous biomaterials for bone replacement: A strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints [J]. Acta Biomaterialia, 2016, 30: 345-356.
[11] AL-KETAN O, ABU AL-RUB R K. MSLattice: A free software for generating uniform and graded lattices based on triply periodic minimal surfaces [J]. Material Design & Processing Communications, 2021, 3(6): e205.
[12] GÓMEZ S, VLAD M D, LÓPEZ J, et al. Design and properties of 3D scaffolds for bone tissue engineering [J]. Acta Biomaterialia, 2016, 42: 341-350.
[13] ZHAO F. Design and PROPERTies of Ti6Al4V radially gradientgyroid lattice based on selective laser melting [D]. Wuhan: Huazhong University of Science and Technology, 2022 (in Chinese).
[14] OLIVARES A L, MARSAL È, PLANELL J A, et al. Finite element study of scaffold architecture design and culture conditions for tissue engineering [J]. Biomaterials, 2009, 30(30): 6142-6149.
[15] ZENG S J, WANG J, HE W H, et al. Mechanical properties of gradient porous dental implants based on SLM [J]. Journal of Netshape Forming Engineering, 2023, 15(1): 61-70 (in Chinese).
[16] MA S, TANG Q, HAN X X, et al. Manufacturability, mechanical properties, mass-transport properties and biocompatibility of triply periodic minimal surface (TPMS) porous scaffolds fabricated by selective laser melting [J]. Materials & Design, 2020, 195: 109034.
[17] ABUEIDDA D W, BAKIR M, ABU AL-RUB R K, et al. Mechanical properties of 3D printed polymeric cellular materials with triply periodic minimal surface architectures [J]. Materials & Design, 2017, 122: 255-267.
[18] WU L, HUANG W, LI X T. Personalized design method of bionic bone scaffold with Voronoi spacial architecture [J]. Journal of Shanghai Jiao Tong University (Science), 2022, 27(4): 521-527.
[19] CILLA M, CHECA S, DUDA G N. Strain shielding inspired re-design of proximal femoral stems for total hip arthroplasty [J]. Journal of Orthopaedic Research, 2017, 35(11): 2534-2544.
[20] ALI D, SEN S. Finite element analysis of mechanical behavior, permeability and fluid induced wall shear stress of high porosity scaffolds with gyroid and lattice-based architectures [J]. Journal of the Mechanical Behavior of Biomedical Materials, 2017, 75: 262-270.
[21] RHO J Y, ASHMAN R B, TURNER C H. Young’s modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements [J]. Journal of Biomechanics, 1993, 26(2): 111-119.
[22] NAGHAVI S A, TAMADDON M, MARGHOUB A, et al. Mechanical characterisation and numerical modelling of TPMS-based gyroid and diamond Ti6Al4V scaffolds for bone implants: An integrated approach for translational consideration [J]. Bioengineering, 2022, 9(10): 504.
[23] ALI D, OZALP M, BLANQUER S B G, et al. Permeability and fluid flow-induced wall shear stress in bone scaffolds with TPMS and lattice architectures: A CFD analysis [J]. European Journal of Mechanics - B/Fluids, 2020, 79: 376-385.
[24] BOBBERT F S L, LIETAERT K, EFTEKHARI A A, et al. Additively manufactured metallic porous biomaterials based on minimal surfaces: A unique combination of topological, mechanical, and mass transport properties [J]. Acta Biomaterialia, 2017, 53: 572-584.
[25] CASTRO A G, PIRES T, SANTOS J E, et al. Permeability versus design in TPMS scaffolds [J]. Materials, 2019, 12(8): 1313.
[26] HEDAYATI R, SADIGHI M, MOHAMMADI-AGHDAM M, et al. Analytical relationships for the mechanical properties of additively manufactured porous biomaterials based on octahedral unit cells [J]. Applied Mathematical Modelling, 2017, 46: 408-422.
[27] TANG Z X, ZHOU Y T, MA L F, et al. Flow performance of porous implants with different geometry: Line, surface, and volume structures [J]. International Journal of Bioprinting, 2023, 9(3): 700.
[28] KARAMAN D, GHAHRAMANZADEH ASL H. The effects of sheet and network solid structures of similar TPMS scaffold architectures on permeability, wall shear stress, and velocity: A CFD analysis [J]. Medical Engineering & Physics, 2023, 118: 104024.
[29] KUMAR J, NIRALA N S, SINGH N K, et al. Design, development and fluidic behavior analysis of triply periodic minimal surface (TPMS) based scaffolds for bone-applications [J]. International Journal on Interactive Design and Manufacturing (IJIDeM), 2024, 18(5): 3077-3087.
[30] GADGIL V, KUMBHOJKAR S, SAPRE T, et al. Investigating wall shear stress and the static pressure in bone scaffolds: A study of porosity and fluid flow dynamics [J]. Biomechanics and Modeling in Mechanobiology, 2025, 24(1): 185-195.
[31] ZHAO F H, VAUGHAN T J, MCNAMARA L M. Quantification of fluid shear stress in bone tissue engineering scaffolds with spherical and cubical pore architectures [J]. Biomechanics and Modeling in Mechanobiology, 2016, 15(3): 561-577.
[32] LI K, ZUO C L, LIAO R B, et al. Optimizing mass transfer performance in triply periodic minimal surface porous scaffolds through isosurface offset [J]. Thin-Walled Structures, 2025, 208: 112800.
[33] GUO F, HU M, WANG C, et al. Studies on the performance of molar porous root-analogue implant by finite element model simulation and verification of a case report [J]. Journal of Oral and Maxillofacial Surgery, 2020, 78(11): 1965.e1-1965.e9.
[34] AN Y H, DRAUGHN R A. Mechanical testing of bone and the bone-implant interface [M]. Boca Raton: CRC Press, 1999.
[35] SCHULTE F A, RUFFONI D, LAMBERS F M, et al. Local mechanical stimuli regulate bone formation and resorption in mice at the tissue level [J]. PLoS One, 2013, 8(4): e62172.
[36] LIU L J, MA S B, ZHANG Y K, et al. Parametric design of porous structure and optimal porosity gradient distribution based on root-shaped implants [J]. Materials, 2024, 17(5): 1137.
[37] ZHANG J G, CHEN P, HU F L, et al. Porous structure design and properties of dental implants [J]. Computer Methods in Biomechanics and Biomedical Engineering, 2024, 27(6): 717-726.
[38] LIU B W, XU W, CHEN M Y, et al. Structural design and finite element simulation analysis of grade 3 graded porous titanium implant [J]. International Journal of Molecular Sciences, 2022, 23(17): 10090.
[39] XU W. Structure design and application of gradient porous Ti-dental implant based on SLM [D]. Beijing: University of Science and Technology Beijing, 2021 (in Chinese).
Outlines

/

〈 〉