[1] Dupont P E, Nelson B J, Goldfarb M, et al. A decade retrospective of medical robotics research from 2010 to 2020 [J]. Science Robotics, 2021, 6(60): eabi8017.
[2] Vigneswaran H T, Schwarzman L S, Francavilla S, et al. A comparison of perioperative outcomes between single-port and multiport robot-assisted laparoscopic prostatectomy [J]. European Urology, 2020, 77(6): 671-674.
[3] Lee S R, Kim J H, Lee Y J, et al. Single-incision versus multiport robotic myomectomy: A propensity score matched analysis of surgical outcomes and surgical tips [J]. Journal of Clinical Medicine, 2021, 10(17): 3957.
[4] Kaouk J H, Haber G P, Autorino R, et al. A novel robotic system for single-port urologic surgery: First clinical investigation [J]. European Urology, 2014, 66(6): 1033-1043.
[5] Cheng C, Tagkalos E, Wu C F, et al. Single-port robotic right upper lobe lobectomy: A case report [J]. JTCVS Techniques, 2023, 20: 162-165.
[6] Shang J Z, Leibrandt K, Giataganas P, et al. A single-port robotic system for transanal microsurgery: Design and validation [J]. IEEE Robotics and Automation Letters, 2017, 2(3): 1510-1517.
[7] Kobayashi Y, Sekiguchi Y, Noguchi T, et al. Development of a robotic system with six-degrees-of-freedom robotic tool manipulators for single-port surgery [J]. The International Journal of Medical Robotics and Computer Assisted Surgery, 2015, 11(2): 235-246.
[8] Haber G P, White M A, Autorino R, et al. Novel robotic da vinci instruments for laparoendoscopic single-site surgery [J]. Urology, 2010, 76(6): 1279-1282.
[9] Xu K, Zhao J R, Fu M X. Development of the SJTU unfoldable robotic system (SURS) for single port laparoscopy [J]. IEEE/ASME Transactions on Mechatronics, 2015, 20(5): 2133-2145.
[10] Seeliger B, Diana M, Ruurda J P, et al. Enabling single-site laparoscopy: The SPORT platform [J]. Surgical Endoscopy, 2019, 33(11): 3696-3703.
[11] Yung K L, Cheung J L K, Chung S W, et al. A single-port robotic platform for laparoscopic surgery with a large central channel for additional instrument [J]. Annals of Biomedical Engineering, 2017, 45(9): 2211-2221.
[12] Quaglia C, Petroni G, Niccolini M, et al. Design of a compact robotic manipulator for single-port laparoscopy [J]. Journal of Mechanical Design, 2014, 136(10): 105001.
[13] Roh S G, Lee Y, Lee J, et al. Development of the SAIT single-port surgical access robot slave arm based on RCM Mechanism [C]//2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Milan: IEEE, 2015: 5285-5290.
[14] Harvey L, Hendrick R, Dillon N, et al. A novel robotic endoscopic device used for operative hysteroscopy [J]. Journal of Minimally Invasive Gynecology, 2020, 27(7): 1631-1635.
[15] Marks J H, Keller D S, Lagares-Garcia J A, et al. Safety and efficacy of a novel miniaturized robotic-assisted surgery system in colectomy: A prospective, investigational device exemption clinical study using the IDEAL framework [J]. Diseases of the Colon and Rectum, 2024, 67(8): 1085-1093.
[16] Sarin A, Samreen S, Moffett J M, et al. Upcoming multi-visceral robotic surgery systems: A SAGES review [J]. Surgical Endoscopy, 2024, 38(12): 6987-7010.
[17] Kang Y H, Kang J S, Cho Y S, et al. A retrospective multicentre study on the evaluation of perioperative outcomes of single-port robotic cholecystectomy comparing the Xi and SP versions of the da Vinci robotic surgical system [J]. The International Journal of Medical Robotics and Computer Assisted Surgery, 2022, 18(1): e2345.
[18] Yang H Z, Wu B B, Liu X, et al. A closed-loop controller for a continuum surgical manipulator based on a specially designed wrist marker and stereo tracking [C]//2020 IEEE/ASME International Conference on Advanced Intelligent Mechatronics. Boston: IEEE, 2020: 335-340.
[19] Li D J, Wang C Y, Guo W, et al. Shape sensing for single-port continuum surgical robot using few multicore fiber Bragg grating sensors [J]. Journal of Shanghai Jiao Tong University (Science), 2023, 28(3): 312-322.
[20] Chen Y Y, Zhang C, Wu Z H, et al. The SHURUI system: A modular continuum surgical robotic platform for multiport, hybrid-port, and single-port procedures [J]. IEEE/ASME Transactions on Mechatronics, 2022, 27(5): 3186-3197.
[21] Liu X, Wu B B, Wu Z H, et al. ParaMaster: Design and experimental characterizations of a haptic device for surgical teleoperation [C]//2020 IEEE/ASME International Conference on Advanced Intelligent Mechatronics. Boston: IEEE, 2020: 375-380.
[22] Wu B B, Liu X, Zhu C X, et al. Design and implementation of a self-calibration method for a dual-arm haptic device [C]//2022 IEEE International Conference on Robotics and Biomimetics. Jinghong: IEEE, 2023: 409-414.
[23] Cameron S. Enhancing GJK: Computing minimum and penetration distances between convex polyhedra [C]//Proceedings of International Conference on Robotics and Automation. Albuquerque: IEEE, 2002: 3112-3117.
[24] Abbas A, Bakhos C, Petrov R, et al. Financial impact of adapting robotics to a thoracic practice in an academic institution [J]. Journal of Thoracic Disease, 2020, 12(2): 89-96.
[25] Ha J, Fagogenis G, Dupont P E. Modeling tube clearance and bounding the effect of friction in concentric tube robot kinematics [J]. IEEE Transactions on Robotics, 2019, 35(2): 353-370.
[26] Ding Y, Wang X, Kuang H M, et al. Incorporating trocar clearance in the kinematics of multi-backbone continuum robots for single-port surgery [C]//2022 IEEE International Conference on Robotics and Biomimetics. Jinghong: IEEE, 2023: 1757-1762.
[27] Xu K, Simaan N. Actuation compensation for flexible surgical snake-like robots with redundant remote actuation [C]//Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. Orlando: IEEE, 2006: 4148-4154.
[28] Chen Y Y, Wu B B, Jin J B, et al. A variable curvature model for multi-backbone continuum robots to account for inter-segment coupling and external disturbance [J]. IEEE Robotics and Automation Letters, 2021, 6(2): 1590-1597.
[29] Webster III R J, Jones B A. Design and kinematic modeling of constant curvature continuum robots: A review [J]. The International Journal of Robotics Research, 2010, 29(13): 1661-1683.
[30] Wang L F, Wu B B, Wang X, et al. Endoscopic image luminance enhancement based on the inverse square law for illuminance and retinex [J]. The International Journal of Medical Robotics and Computer Assisted Surgery, 2022, 18(4): e2396.
[31] Peng D, Jing T L, Yao X L, et al. Preliminary experience of partial nephrectomy through a new single-port surgical robot system [J]. Journal of Endourology, 2023, 37(5): 535-541.
[32] Zhang C, Wei Y, Jing T, et al. Feasibility and safety of a novel single-port robotic surgical system in radical prostatectomy: Initial experiences [J]. Chinese Journal of Endourology (Electronic Edition), 2022, 16(4): 293-297 (in Chinese).
[33] Zhu Q Y, Zhang C, Wei Y, et al. Preliminary application of a domestic single-port robotic surgical system in retroperitoneal partial nephrectomy and partial adrenalectomy [J]. Academic Journal of Naval Medical University, 2022, 43(10): 1189-1193 (in Chinese).
[34] Chang R, Duan P, Shen Y, et al. Effectiveness and safety of SR-ENS-600 endoscopic surgical system in benign and malignant gynecological diseases: A prospective, multicenter, clinical trial with 63 cases [J]. Journal of Robotic Surgery, 2024, 18(1): 210.
[35] Guo Z C, Shi Y Q, Song Z J, et al. Single-incision robotic assisted surgery: A nonrandomized cohort pilot study on a novel surgical platform in colorectal surgery [J]. International Journal of Surgery, 2023, 109(11): 3417-3429.