Depth Camera-Based Robot-Assisted Ultrasonic Lipolysis System

Expand
  • (1. Institute of Forming Technology & Equipment, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200030, China; 2. Department of Plastic Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China; 3. Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200030, China)

Received date: 2020-12-30

  Online published: 2022-01-14

Abstract

With many advantages such as non-invasive, safe and quick effect, focused ultrasound lipolysis stands out among many fat-removing methods. However, during the whole process, the doctor needs to hold the ultrasound transducer and press it on the patient’s skin with a large pressure for a long time; thus the probability of muscle and bone damage for doctors is greatly increased. To reduce the occurrence of doctors’ occupational diseases, a depth camera-based ultrasonic lipolysis robot system is proposed to realize robot-assisted automatic ultrasonic lipolysis operation. The system is composed of RealSense depth camera, KUKA LBR Med seven-axis robotic arm, PC host, and ultrasonic lipolysis instrument. The whole operation includes two parts: preoperative planning and intraoperative operation. In preoperative planning, the treatment area is selected in the camera image by the doctor; then the system automatically plans uniformly distributed treatment points in the treatment area. At the same time, the skin normal vector is calculated to determine the end posture of the robot, so that the ultrasound transducer can be pressed down in the normal direction of skin. During the intraoperative operation, the robot is controlled to arrive at the treatment point in turn. Meanwhile, the patient’s movement can be detected by the depth camera, and the path of robot is adjusted in real time so that the robot can track the movement of patient, thereby ensuring the accuracy of the ultrasonic lipolysis operation. Finally, the human body model experiment is conducted. The results show that the maximum error of the robot operation is within 5mm, average error is 3.1mm, and the treatment points of the robot operation are more uniform than those of manual operation. Therefore, the system can replace the doctor and achieve autonomous ultrasonic lipolysis to reduce the doctor’s labor intensity.

Cite this article

YAN Minpeng (严旻芃), CHAI Gang ∗ (柴岗), XIE Le ∗ (谢叻) . Depth Camera-Based Robot-Assisted Ultrasonic Lipolysis System[J]. Journal of Shanghai Jiaotong University(Science), 2022 , 27(1) : 36 -44 . DOI: 10.1007/s12204-021-2343-z

References

[1] NG M, FLEMING T, ROBINSON M, et al. Global,regional, and national prevalence of overweight andobesity in children and adults during 1980–2013: Asystematic analysis for the Global Burden of DiseaseStudy 2013 [J]. The Lancet, 2014, 384(9945): 766-781. [2] WU Y, MA G, HU Y, et al. The current prevalencestatus of body overweight and obesity in China: Datafrom the China National Nutrition and Health Survey[J]. Chinese Journal of Preventive Medicine, 2005,39(5): 316-320 (in Chinese). [3] MACKAY J, MENSAH G. The atlas of heart diseaseand stroke [M]. Geneva: WHO, 2004: 5-6. [4] JASTREBOFF A M, KOTZ C M, KAHAN S, et al.Obesity as a disease: The obesity society 2018 positionstatement [J]. Obesity, 2019, 27(1): 7-9. [5] LO J C, CHANDRAM, SINAIKO A, et al. Severe obesityin children: Prevalence, persistence and relationto hypertension [J]. International Journal of PediatricEndocrinology, 2014, 2014(1): 3. [6] LOU G, CHEN J. The status and progress of FocusedUltrasound in lipolysis [J]. Chinese Journal of AestheticMedicine, 2015, 24(7): 85-89 (in Chinese). [7] FATEMI A. High-intensity focused ultrasound effectivelyreduces adipose tissue [J]. Seminars in CutaneousMedicine and Surgery, 2009, 28(4): 257-262. [8] HUANG P, HUANG F, ZHAO B, et al. Attentionmust be paid to occupational injuries of sonographers[J]. Chinese Journal of Ultrasound in Medicine, 2010,26(12): 1141-1143 (in Chinese). [9] CLAES F, BERGER J, STASSIJNS G. Arm and neckpain in ultrasonographers [J]. Human Factors, 2015,57(2): 238-245. [10] MIYAMOTO H, LEECHAVENGVONGS S, ATIK T,et al. Nerve transfer to the deltoid muscle using thenerve to the long head of the triceps with the da Vincirobot: Six cases [J]. Journal of Reconstructive Microsurgery,2014, 30(6): 375-380. [11] PIERROT F, DOMBRE E, D′EGOULANGE E, et al.Hippocrate: a safe robot arm for medical applicationswith force feedback [J]. Medical Image Analysis, 1999,3(3): 285-300. [12] CONTI F, PARK J, KHATIB O. Interface design andcontrol strategies for a robot assisted ultrasonic examinationsystem [M]//Experimental Robotics. BerlinHeidelberg: Springer, 2014: 97-113. [13] GRAVETT M, CEPEK J, FENSTER A. An ultrahighfield strength MR image-guided robotic needledelivery system for in-bore small animal interventions[J]. Medical Physics, 2017, 44(11): 5544-5555. [14] DUAN B, RONG W, CHNG C B, et al. Image-guidedrobotic system for radiofrequency ablation of largeliver tumor with single incision [C]//2015 12th InternationalConference on Ubiquitous Robots and AmbientIntelligence (URAI). Goyangi: IEEE, 2015: 284-289. [15] GRAUMANN C, FUERST B, HENNERSPERGER C,et al. Robotic ultrasound trajectory planning for volumeof interest coverage [C]//2016 IEEE InternationalConference on Robotics and Automation (ICRA).Stockholm: IEEE, 2016: 736-741. [16] WU J, JIANG H,WANG X. A method for the decisionof a point whether in or not in self-intersected polygon[J]. Acta Simulata Systematica Sinica, 2003, 15(11):1592-1594 (in Chinese).
Outlines

/