Combined with the advantages and disadvantages of tuned liquid damper (TLD) and tuned mass damper (TMD), a double tuned liquid mass damper (TLMD) is proposed by replacing the rigid connection of TLD with the spring structure. The motion equation of a single-degree-of-freedom structure with a TLMD attached at its top is found under harmonic excitation. Comparing the energy consumption and amplitude of primary structure with equal mass ratio TMD, it is found that the energy dissipation performance of TLMD is better in the effective phase region. The interaction process between TLMD and structure is analyzed, and the formula of phase deviation between the relative velocity of tank and the displacement of primary structure is deduced. By analyzing the influence of mass ratio, frequency ratio, damping ratio and water depth ratio on the damping effect, the results show that the frequency ratio and liquid depth ratio have great influence on the size and location of deep resonance peak, and the mass ratio and damping ratio have great influence on the width of the effective frequency band. The formula of equivalent damping ratio is proposed based on the principle of energy and it is found that the equivalent damping ratio is related to the phase deviation and change with the frequency ratio of the external excitation.
HU Jingjing, XU Jiayun
. Parameter Optimization and Control Characteristics Analysis of TLMD System Based on Phase Deviation[J]. Journal of Shanghai Jiaotong University(Science), 2020
, 25(3)
: 372
-383
.
DOI: 10.1007/s12204-019-2148-5
[1] BANDIVADEKAR T P, JANGID R S. Mass distribution of multiple tuned mass dampers for vibration control of structures [J]. International Journal of Civil and Structural Engineering, 2012, 3(1): 91-113.
[2] LU Z, WANG D C, ZHOU Y. Experimental parametric study on wind-induced vibration control of particle tuned mass damper on a benchmark high-rise building[J]. Structural Design of Tall and Special Buildings,2017, 26(8): e1359.
[3] KIM Y M, YOU K P, KIM H Y. Wind-induced excitation control of a tall building with tuned mass dampers[J]. Structural Design of Tall and Special Buildings,2008, 17(3): 669-682.
[4] TAIT M J, DENG X. The performance of structuretuned liquid damper systems with different tank geometries [J]. Structural Control & Health Monitoring,2010, 17(3): 254-277.
[5] SOTO M G, ADELI H. Tuned mass dampers [J]. Archives of Computational Methods in Engineering,2013, 20(4): 419-431.
[6] BANERJI P, MURUDI M, SHAH A H, et al. Tuned liquid dampers for controlling earthquake response of structures [J]. Earthquake Engineering & Structural Dynamics, 2000, 29(5): 587-602.
[7] SADEK F, MOHRAZ B, TAYLOR A W, et al. A method of estimating the parameters of tuned mass dampers for seismic applications [J]. Earthquake Engineering & Structural Dynamics, 1997, 26(6): 617-635.
[8] DANIEL Y, LAVAN O, LEVY R. Multiple-tuned mass dampers for multimodal control of pedestrian bridges [J]. Journal of Structural Engineering, 2012, 138(9):1173-1178.
[9] MIN KW, KIM J, KIM Y W. Design and test of tuned liquid mass dampers for attenuation of the wind responses of a full scale building [J]. Smart Materials and Structures, 2014, 23(4): 045020.
[10] TAIT M J. Modelling and preliminary design of a structure-TLD system [J]. Engineering Structures,2008, 30(10): 2644-2655.
[11] RUIZ R O, LOPEZ-GARCIA D, TAFLANIDIS A A. Modeling and experimental validation of a new type of tuned liquid damper [J]. Acta Mechanica, 2016,227(11): 3275-3294.
[12] BANERJI P, SAMANTA A. Earthquake vibration control of structures using hybrid mass liquid damper[J]. Engineering Structures, 2011, 33(4): 1291-1301.
[13] HEO J S, LEE S K, PARK E, et al. Performance test of a tuned liquid mass damper for reducing bidirectional responses of building structures [J]. Structural Design of Tall and Special Buildings, 2009, 18(7): 789-805.
[14] HUANG D Y, ZHOU F L, TAN P, et al. Vibration control strategies of controllable TMD-TLD hybrid system for offshore platforms [J]. Journal of Dalian Maritime University, 2008, 34(1): 1-4(in Chinese).
[15] HUANG D Y. Research on performance improvement of tuned type dampers [D]. Harbin: Harbin Institute of Technology, 2010(in Chinese).
[16] SAITO T, SHIBA K, TAMURA K. Vibration control characteristics of a hybrid mass damper system installed in tall buildings [J]. Earthquake Engineering & Structural Dynamics, 2001, 30(11): 1677-1696.
[17] KALOOP M R, HU J W, BIGDELI Y. The performance of structure-controller coupled systems analysis using probabilistic evaluation and identification model approach [J]. Shock and Vibration, 2017, 2017:5482307.
[18] FU C. Transforming method of TLCD-structure to TMD-structure for vibration control [J]. KSCE Journal of Civil Engineering, 2018, 22(4): 1384-1393.
[19] BIGDELI Y, KIM D. Damping effects of the passive control devices on structural vibration control: TMD,TLC and TLCD for varying total masses [J]. KSCE Journal of Civil Engineering, 2016, 20(1): 301-308.
[20] SONG T T, DARDUSH G F. Passive energy dissipation systems in structural engineering [M]. New York:John Wiley & Sons, 1997.
[21] CHUNG L L, LAI Y A, YANG C S W, et al. Semiactive tuned mass dampers with phase control [J].Journal of Sound and Vibration, 2013, 332(15): 3610-3625.
[22] NOVO T, VARUM H, TEIXEIRA-DIAS F, et al.Tuned liquid dampers simulation for earthquake response control of buildings [J]. Bulletin of Earthquake Engineering, 2014, 12(2): 1007-1024.
[23] LEE S C, REDDY D V. Frequency tuning of offshore platforms by liquid sloshing [J]. Applied Ocean Research,1982, 4(4): 226-231.
[24] NOJI T, YOSHIDA H, TATSUMI E, et al. Study of water-sloshing vibration control damper (Part 1):Hydrodynamic force characteristics of the device and damping effect of the system [J]. Journal of Structural and Construction Engineering, 1990, 411(5): 97-105(in Japanese).
[25] DENG X, TAIT M J. Equivalent mechanical models of tuned liquid dampers with different tank geometries[J]. Canadian Journal of Civil Engineering, 2008,35(10): 1088-1101.
[26] LI C X, XIONG X Y. Optimum multiple tuned mass dampers based on ADMF and the combinations available of the system parameters under earthquake [J].Chinese Journal of Computational Mechanics, 2002,19(3): 291-298(in Chinese).
[27] LEE S H, MIN K W, HWANG J S, et al. Evaluation of equivalent damping ratio of a structure with added dampers [J]. Engineering Structures, 2004, 26(3): 335-346.