基于三维空间的新型配电网关键技术时空适应性评估
|
刘东铭, 曾庆彬, 张勇军, 张军, 樊玮, 刘宇
|
Spatio-Temporal Adaptation Assessment of Key Technologies of New Distribution Network Based on 3D Space
|
LIU Dongming, ZENG Qingbin, ZHANG Yongjun, ZHANG Jun, FAN Wei, LIU Yu
|
|
表4 指标权重计算结果
|
Tab.4 Index weight
|
|
指标 | C-OWA | AHP | Uj | CRITIC | | A11 | 0.6625 | 0.2509 | 0.1662 | 0.0274 | 0.0821 | A12 | 0.8000 | 0.4072 | 0.3258 | 0.0351 | 0.1302 | A13 | 0.4938 | 0.1208 | 0.0597 | 0.0342 | 0.0550 | A14 | 0.3250 | 0.0546 | 0.0177 | 0.0326 | 0.0292 | A15 | 0.3312 | 0.0643 | 0.0213 | 0.0326 | 0.0321 | A21 | 0.2687 | 0.0407 | 0.0109 | 0.0289 | 0.0216 | A22 | 0.3688 | 0.0615 | 0.0227 | 0.0555 | 0.0432 | B11 | 0 | 0.0364 | 0 | 0.0548 | 0 | B12 | 0.0688 | 0.0628 | 0.0043 | 0.0438 | 0.0167 | B13 | 0 | 0.0364 | 0 | 0.0647 | 0 | B14 | 0 | 0.0364 | 0 | 0.0631 | 0 | B15 | 0.8688 | 0.4904 | 0.4261 | 0.0317 | 0.1415 | B21 | 0.1250 | 0.0891 | 0.0111 | 0.0265 | 0.0209 | B22 | 0.0313 | 0.0698 | 0.0022 | 0.0279 | 0.0095 | B23 | 0 | 0.0379 | 0 | 0.0594 | 0 | B24 | 0.2000 | 0.1408 | 0.0282 | 0.0295 | 0.0351 | C11 | 0.8938 | 0.2674 | 0.2390 | 0.0324 | 0.1071 | C12 | 0.8938 | 0.2674 | 0.2390 | 0.0303 | 0.1036 | C13 | 0.0688 | 0.0335 | 0.0023 | 0.0298 | 0.0101 | C21 | 0 | 0.0215 | 0 | 0.0268 | 0 | C22 | 0 | 0.0215 | 0 | 0.0614 | 0 | C23 | 0 | 0.0215 | 0 | 0.0462 | 0 | C24 | 0 | 0.0215 | 0 | 0.0291 | 0 | C31 | 0.7750 | 0.1811 | 0.1404 | 0.0305 | 0.0796 | C32 | 0.7000 | 0.1152 | 0.0806 | 0.0325 | 0.0623 | C41 | 0.1688 | 0.0494 | 0.0083 | 0.0333 | 0.0202 | C42 | 0.2000 | 0.1408 | 0.0282 | 0.0295 | 0.0351 |
|
|
|