考虑频率稳定约束的电-氢互补多楼宇协调优化调度
范宏, 王兰坤, 邢梦晴, 田书欣, 于伟南

Coordinated Scheduling of Multiple Buildings with Electric-Hydrogen Complementary Considering Frequency Stability Constraints
FAN Hong, WANG Lankun, XING Mengqing, TIAN Shuxin, YU Weinan
表1 发电机组参数
Tab.1 Parameters of generator set
参数 取值 参数 取值
P 1 W , m a x/kW 100 P 3 G , m a x/kW 100
H 1 W/s 8 H 3 G/s 5
δ 1 W/% 4 δ 3 G/% 5
P 2 W , m a x/kW 120 P 1 F C , m a x/kW 70
H 2 W/s 8 H 1 H S/s 1~3
δ 2 W/% 5 δ 1 H S/% 3
P 1 G , m a x/kW 80 P 2 F C , m a x/kW 90
H 1 G/s 4.8 H 2 H S/s 1~3
δ 1 G/% 4.5 δ 2 H S/% 3.5
P 2 G , m a x/kW 80 P 3 F C , m a x/kW 100
H 2 G/s 4.8 H 3 H S/s 1~3
δ 2 G/% 4.5 δ 3 H S/% 3.5