Processing math: 100%

考虑频率稳定约束的电-氢互补多楼宇协调优化调度
范宏, 王兰坤, 邢梦晴, 田书欣, 于伟南

Coordinated Scheduling of Multiple Buildings with Electric-Hydrogen Complementary Considering Frequency Stability Constraints
FAN Hong, WANG Lankun, XING Mengqing, TIAN Shuxin, YU Weinan
表1 发电机组参数
Tab.1 Parameters of generator set
参数 取值 参数 取值
PW,max1/kW 100 PG,max3/kW 100
HW1/s 8 HG3/s 5
δW1/% 4 δG3/% 5
PW,max2/kW 120 PFC,max1/kW 70
HW2/s 8 HHS1/s 1~3
δW2/% 5 δHS1/% 3
PG,max1/kW 80 PFC,max2/kW 90
HG1/s 4.8 HHS2/s 1~3
δG1/% 4.5 δHS2/% 3.5
PG,max2/kW 80 PFC,max3/kW 100
HG2/s 4.8 HHS3/s 1~3
δG2/% 4.5 δHS3/% 3.5