基于PCA-ELM的红外多光谱辐射测温
|
席剑辉, 姜瀚, 陈博, 傅莉
|
Infrared Multispectral Radiation Temperature Measurement Based on PCA-ELM
|
XI Jianhui, JIANG Han, CHEN Bo, FU Li
|
|
表3 黑体的测温结果及其相对误差
|
Tab.3 Temperature measurement results of blackbody and its relative errors
|
|
T1/℃ | T2/℃ | /% | | /% | 95 | 97.4762 | 2.61 | 0.9318 | 4.8 | 115 | 119.1212 | 3.58 | 0.9673 | 1.3 | 135 | 131.8413 | 2.34 | 1.0110 | 3.2 | 155 | 150.7401 | 2.75 | 1.0217 | 4.3 | 180 | 176.3031 | 2.05 | 1.0151 | 3.6 | 450 | 455.9431 | 1.32 | 0.9410 | 4.0 | 520 | 517.7082 | 0.44 | 0.9688 | 1.1 | 1000 | 1025.3000 | 2.53 | 0.9523 | 2.8 |
|
|
|