R290双水路空调系统降燃增效设计

展开
  • 1.重庆交通大学机电与车辆工程学院,重庆 400074; 2.重庆建设汽车系统股份有限公司汽车热管理系统研究院,重庆 400052
姜龙辉(2001—),硕士生,从事新能源汽车空调热管理研究
何泽银,教授;E-mail:hezeyin@cqjtu.edu.cn

网络出版日期: 2026-10-01

R290 Dual-Channel Air Conditioning System is Designed for Fuel Reduction and Efficiency

Expand
  • 1. School of Mechanical and Vehicle Engineering,Chongqing Jiaotong University, Chongqing 400074, China; 2. Chongqing Construction Automobile System Co., Ltd., Chongqing 400052, China

Online published: 2026-10-01

摘要

针对电动汽车空调系统采用R290制冷剂替换传统制冷剂时引发的制冷性能衰减和燃爆问题,搭建压缩机-冷凝器-膨胀阀-蒸发器-单水路循环的空调系统制冷模型,在环境温度为35℃工况下分析不同压缩机转速时R290与传统工质(R134a)空调系统制冷性能;进而,建立压缩机-冷凝器-膨胀阀-蒸发器-双水路循环的空调系统模型,研究水泵转速、压缩机转速和制冷剂充注量对系统性能系数(COP)的影响;而后,构建R290双水路空调系统降燃增效优化模型,基于多目标遗传优化算法提高系统COP与制冷量。结果表明:R290双水路空调系统可替代传统工质单水路空调系统;双水路空调系统降燃增效优化后,充注量降低了24%,COP提高了21.3%。研究结果可为电动汽车空调系统降燃增效提供理论参考。

本文引用格式

姜龙辉, 何泽银, 王建辉, 周亚伟, 郁修阳 . R290双水路空调系统降燃增效设计[J]. 上海交通大学学报, 0 : 1 . DOI: 10.16183/j.cnki.jsjtu.2025.421

Abstract

In response to the cooling performance degradation and flammability issues caused by replacing traditional refrigerants with R290 refrigerant in electric vehicle air conditioning systems, a refrigeration model of an air conditioning system with a compressor-condenser-expansion valve-evaporator-single water loop cycle was established. The cooling performance of R290 and traditional refrigerant (R134a) air conditioning systems at different compressor speeds was analyzed under an ambient temperature of 35°C. Furthermore, a compressor-condenser-expansion valve-evaporator-double water loop cycle air conditioning system model was developed to study the effects of water pump speed, compressor speed, and refrigerant charge on the system coefficient of performance (COP). Subsequently, an optimization model for the R290 double water loop air conditioning system for fuel reduction and efficiency improvement was constructed, using a multi-objective genetic optimization algorithm to enhance system COP and cooling capacity. The results can provide a theoretical reference for improving the refrigeration performance of the electric vehicle air conditioning; after optimization for fuel reduction and efficiency improvement, the charge decreased by 24% and the COP increased by 21.3%. The research results can provide theoretical reference for fuel reduction and efficiency improvement in electric vehicle air conditioning systems.
文章导航

/

〈 〉