双层膜结构体育馆夏季热环境监测与分析
收稿日期: 2021-07-12
修回日期: 2021-11-08
录用日期: 2021-12-16
网络出版日期: 2023-03-01
基金资助
国家自然科学基金项目(51778362);国家自然科学基金项目(51608320)
Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
Received date: 2021-07-12
Revised date: 2021-11-08
Accepted date: 2021-12-16
Online published: 2023-03-01
膜结构屋面因其对自然光源的充分利用和形式灵活等优势而在体育场馆等大跨度建筑中广泛应用,为解决其保温隔热性能差、易受外界环境因素影响等突出问题,多层膜结构设计、铺设保温层等方案被应用于工程实践,但热环境监测及分析的相关研究仍存在空白.为了研究双层聚四氟乙烯-气凝胶屋面体育馆的热环境,多点均匀布置测温仪进行监测,利用实测数据构建整体温度场;建立能够准确反映温度场变化的热物理模型,平均误差小于5%;以屋面保温层铺设为变量,基于该模型(原始工况)构建了无保温层、仅岩棉保温层和全为气凝胶保温层3种工况.对比发现,气凝胶的铺设使得室内空间的平均温度降低了2.0 ℃;原始工况的保温隔热效果最佳,室内外平均温差为9.6 ℃,研究可为膜结构屋面的保温隔热设计提供参考.
宋寅搏, 阴悦, 闫勇升, 王晓情, 陈务军, 任思杰 . 双层膜结构体育馆夏季热环境监测与分析[J]. 上海交通大学学报, 2023 , 57(2) : 183 -193 . DOI: 10.16183/j.cnki.jsjtu.2021.259
The membrane structure roof is widely used in large-span buildings such as stadiums and gymnasiums because of its full use of natural light sources and flexible forms. In order to solve the prominent problems such as poor thermal insulation performance and prone to external environmental factors, the multi-layer membrane structure design, laying of insulation layers, and other schemes are applied to engineering practice. However, there is still a gap in the relevant research of thermal environment monitoring and analysis. In order to study the thermal environment of the double-layer PTFE (polytetrafluoroethylene)-aerogel roof, multi-point thermometers were uniformly arranged to monitor, and the overall temperature field was constructed using the measured data. A thermophysical model which could accurately reflect the change of temperature field was established, whose average error was less than 5%. With the laying of roof insulation layer as the variable, three working conditions, i.e., no insulation layer, only rock wool insulation layer, and all aerogel insulation layer were constructed based on the model. The comparison indicates that the laying of aerogel reduces the average temperature of indoor space by 2.0 ℃, the original working condition has the best thermal insulation effect, and the average temperature difference between indoor and outdoor is 9.6 ℃. This paper can provide reference for the thermal insulation design of membrane structure roofs.
Key words: membrane structure; thermal environment; enclosed gymnasium; aerogel
[1] | GURLICH D, REBER A. Daylight performance of a translucent textile membrane roof with thermal insulation[J]. Buildings, 2018, 8(9): 118-137. |
[2] | HU J H, CHEN W J. Safety and serviceability of membrane buildings: A critical review on architectural, material and structural performance[J]. Engineering Structures, 2020, 210: 110292. |
[3] | LIU H B, LI B. Solar radiation properties of common membrane roofs used in building structures[J]. Materials & Design, 2016, 105: 268-277. |
[4] | TIAN G J, FAN Y S. Analysis of solar radiation heat transfer of architectural fabric membrane material[J]. Journal of Engineered Fibers and Fabrics, 2020, 15(2): 1-6. |
[5] | HU J H, CHEN W J. Thermal characteristics and comfort assessment of enclosed large-span membrane stadiums[J]. Applied Energy, 2018, 229: 728-735. |
[6] | TIAN G J, FAN Y S. Indoor thermal environment of thin membrane structure buildings: A review[J]. Energy and Buildings, 2021, 234: 110704. |
[7] | ZHANG T T, TAN Y F. The application of air layers in building envelopes: A review[J]. Applied Energy, 2016, 165: 707-734. |
[8] | TANG H D, ZHANG T. On-site measured performance of a mechanically ventilated double etfe cushion structure in an aquatics center[J]. Solar Energy, 2018, 162: 289-299. |
[9] | SUO H, ANGELOTTI A. Thermal-physical behavior and energy performance of air-supported membranes for sports halls: A comparison among traditional and advanced building envelopes[J]. Energy and Buildings, 2015, 109: 35-46. |
[10] | KOSTIC D, MILOSEVIC V. Influence of single and double membrane roofs on thermal behaviour of enclosed space[J]. Tehnicki Vjesnik-Technical Gazette, 2018, 25: 188-196. |
[11] | GHANI S, ELBIALY E A. Thermal performance of sta-dium’s field of play in hot climates[J]. Energy and Buildings, 2017, 139: 702-718. |
[12] | FANTUCCI S, FENOGLIO E. Development of an aerogel-based thermal coating for the energy retrofit and the prevention of condensation risk in existing buildings[J]. Science and Technology for the Built Environment, 2019, 25(9): 1178-1186. |
[13] | GAO T, IHARA T. Perspective of aerogel glazings in energy efficient buildings[J]. Building and Environment, 2016, 95: 405-413. |
[14] | BURATTI C, BELLONI E. Aerogel glazing systems for building applications: A review[J]. Energy and Buildings, 2021, 231: 110587. |
[15] | SADINENI S B, MADALA S. Passive building energy savings: A review of building envelope components[J]. Renewable & Sustainable Energy Reviews, 2011, 15(8): 3617-3631. |
/
〈 |
|
〉 |